background image

7

Name of Parts

Remote Controller

Signal transmitter

Receiver

To use the remote controller, aim the 

• 

transmitter at the indoor unit. If there 
is anything to block signals between 
the unit and the remote controller, 
such as a curtain, the unit will not 
operate.
Do not drop the remote controller. Do 

• 

not get it wet.
The maximum distance for 

• 

communication is approx. 7m.

FAN setting button

It selects the air

fl

 ow rate setting. 

• 

 

 Page  14

POWERFUL button

POWERFUL operation. 

• 

 Page  17

Display (LCD)

It displays the current settings.

• 

(In this illustration, each section is 
shown with all its displays on for the 
purpose of explanation.)

TEMPERATURE 
adjustment buttons

It changes the temperature setting.

• 

 

 Page  12

ON/OFF button

Press this button once to start 

• 

operation.
Press once again to stop it. 

 Page  11

Front cover

Open the front cover. 

• 

 Page  8

HEAT PUMP model

ARC452A4

COOLING ONLY model

ARC452A13

01_EN_3P266960-1A.indd   7

01_EN_3P266960-1A.indd   7

6/1/2011   9:16:08 AM

6/1/2011   9:16:08 AM

Содержание FTXS50KAVMN

Страница 1: ...N MANUAL MODELS FTXS50KVMA FTXS60KVMA FTXS71KVMA FTKS50KVMA FTKS60KVMA FTKS71KVMA FTKS50KAVMA FTKS60KAVMA FTKS71KAVMA FTXS50KAVMA FTXS60KAVMA FTXS71KAVMA FTXS50KAVMN FTXS60KAVMN FTXS71KAVMN 00_CV_3P26...

Страница 2: ...of the outdoor unit This function is useful when you need to consideration for your neighborhood Page 18 INTELLIGENT EYE The INTELLIGENT EYE sensor detects the human movement in a room If no one is r...

Страница 3: ...ration 18 ECONO Operation 19 OFF TIMER Operation 20 ON TIMER Operation 21 WEEKLY TIMER Operation 22 Multi Connectio n Note for Multi System 28 Car e Care and Cleaning 30 Troubleshootin g Troubleshooti...

Страница 4: ...ner or otherwise fire may result Beware of fire in case of refrigerant leakage If the air conditioner is not operating correctly i e not generating cool or warm air refrigerant leakage could be the ca...

Страница 5: ...nly connect the air conditioner to the specified power supply circuit Power supplies other than the one specified may result in electric shocks overheating and fires Arrange the drain hose to ensure s...

Страница 6: ...troller When the unit receives a signal you will hear a beep sound Case Sound type Operation start beep beep Setting changed beep Operation stop long beep Display Indoor unit ON OFF switch Press this...

Страница 7: ...the front panel Air filter Titanium apatite deodorizing filter Refrigerant piping and inter unit wiring Earth terminal It is inside of this cover Drain hose Air inlet back and side Air outlet Outdoor...

Страница 8: ...t selects the airflow rate setting Page 14 POWERFUL button POWERFUL operation Page 17 Display LCD It displays the current settings In this illustration each section is shown with all its displays on f...

Страница 9: ...OFF TIMER and WEEKLY TIMER settings Page 20 21 22 QUIET button OUTDOOR UNIT QUIET operation Page 18 COMFORT SENSOR button COMFORT AIRFLOW and INTELLIGENT EYE operation Page 15 16 OFF TIMER button Pag...

Страница 10: ...the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both 2 batteries with new size AAA LR03 alkaline The attached batteries...

Страница 11: ...d closes once to set the reference position To set the clock Press 1 is displayed and blink Press 2 to set the current day of the week Press 3 blinks Press 4 to set the clock to the present time Holdi...

Страница 12: ...he room After the start of heating operation it takes some time before the room gets warmer In HEAT operation frost may occur on the outdoor unit and lower the heating capacity In that case the system...

Страница 13: ...ll amount of electricity even while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off Use the air conditioner i...

Страница 14: ...g The 3 D airflow direction Press and and are displayed on the LCD The flaps and louvers move in turn To cancel 3 D airflow press either or again The flaps or louvers will stop moving To set the flaps...

Страница 15: ...n Upper limit Lower limit and COMFORT AIRFLOW Upper limit Lower limit Stop operation 5 10 40 15 55 5 55 Note on 3 D airflow Using 3 D airflow circulates cold air which tends to collected at the bottom...

Страница 16: ...g operation The set temperature is shifted in 2 C steps Someone is back in the room Back to normal operation The air conditioner will return to normal operation when the sensor detects the movement of...

Страница 17: ...Application range is as follows 90 55 7m 55 Vertical angle 90 Side view Horizontal angle 110 Top view 7m Sensor may not detect moving objects further than 7m away Check the application range Sensor de...

Страница 18: ...POWERFUL operation cannot be used together with ECONO COMFORT AIRFLOW or OUTDOOR UNIT QUIET operation Priority is given to the function of whichever button is pressed last POWERFUL operation can only...

Страница 19: ...TDOOR UNIT QUIET operation will work only when this function is set on all operated indoor units However if using priority room setting refer to Note for multi system Page 28 This function is availabl...

Страница 20: ...me Time Maximum during normal operation Maximum during ECONO Mode Normal operation ECONO Mode From start up until set temperature is reached Running current and power consumption This diagram is a rep...

Страница 21: ...D The TIMER lamp lights up Display To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off NOTE Notes on TIMER...

Страница 22: ...time are displayed on the LCD The TIMER lamp lights up Display To cancel ON TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp go...

Страница 23: ...age 25 6 00 8 30 17 30 22 00 25 C 27 C Program 1 Program 2 Program 3 Program 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings up to programs 1 4 Page 23 8 00 10 00 19 00 21 00 27...

Страница 24: ...be displayed 1 to 4 settings can be made per day Press 2 to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week Press 3 The day o...

Страница 25: ...nnot be used to go back to the reservation number 6 Press to select the desired time The time can be set between 0 00 and 23 50 in 10 minute intervals To return to the ON OFF TIMER mode setting press...

Страница 26: ...ill be copied Press 4 to select the destination day of the week Press 5 The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be cop...

Страница 27: ...tion number and press The mode is switched to setting mode Go to Setting mode STEP 4 Page 23 Press 3 to exit confirming mode is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER l...

Страница 28: ...TIMER operation will be activated The reservations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting rese...

Страница 29: ...tting active Refer to Priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programming during installation Please consult your re...

Страница 30: ...in room B C and D Status of room B C and D when the unit in room A is in COOL mode COOL or DRY or FAN Current operation mode maintained HEAT The unit enters standby mode Operation resumes when the ro...

Страница 31: ...sure to stop the operation and turn the breaker off Do not touch the aluminum fins of the indoor unit If you touch those parts this may cause an injury Air filter Vacuum dust or wash the filter Once...

Страница 32: ...one side Front panel shaft 1 Slide 2 Pull 1 Slide 2 Pull Disconnect the front panel shaft on the other side in the same manner Clean the front panel 2 Wipe it with a soft cloth soaked in water Only ne...

Страница 33: ...hem with vacuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then dry t...

Страница 34: ...ement Remove the tabs on the filter frame and replace with a new filter Do not throw away the filter frame Reuse the filter frame when replacing the titanium apatite deodorizing filter Dispose of the...

Страница 35: ...e service shop if this is the case Before a long idle period Operate the FAN only for several hours on a fine day to dry 1 out the inside Press and select operation Press and start the operation After...

Страница 36: ...s sound is generated when refrigerant flows during defrosting operation Clicking sound during operation or idle time This sound is generated when the refrigerant control valves or the electrical parts...

Страница 37: ...p flashes Are the air filters clean Clean the air filters Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Turn the bleaker off and take all obstacles away Th...

Страница 38: ...the right as shown in the illustration so that the AUTO and HEAT mode displays will disappear DIP switch Heat pump model Cooling only model DIP switch The ON OFF TIMER does not operate according to th...

Страница 39: ...r leaks from the indoor unit Turn the breaker off and call the service shop After a power failure The air conditioner automatically resumes operation in about 3 minutes You should just wait for a whil...

Страница 40: ...AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE...

Страница 41: ...40 MEMO 01_EN_3P266960 1A indd 40 01_EN_3P266960 1A indd 40 6 1 2011 9 16 57 AM 6 1 2011 9 16 57 AM...

Страница 42: ...41 MEMO 01_EN_3P266960 1A indd 41 01_EN_3P266960 1A indd 41 6 1 2011 9 16 57 AM 6 1 2011 9 16 57 AM...

Страница 43: ...42 MEMO 01_EN_3P266960 1A indd 42 01_EN_3P266960 1A indd 42 6 1 2011 9 16 57 AM 6 1 2011 9 16 57 AM...

Страница 44: ...3P266960 1D M09B394C 2009 HT Two dimensional bar code is a code for manufacturing Quick Reference 00_CV_3P266960 1D indd 2 21 Oct 20 2 15 27 PM...