5
|
About the unit
Installer reference guide
19
FTXP-N
Daikin room air conditioner
4P518023-14L – 2022.06
5 About the unit
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
5.1 System layout
a
g
d
f
e
c
b
a
Indoor unit
b
Wireless LAN adapter
c
Service lid
d
Air filter
e
Titanium apatite deodorising and the silver particle filter (Ag-ion filter)
f
Refrigerant piping, drain hose and interconnection cable
g
Insulation tape
5.2 Operation range
Use the system in the following temperature and humidity ranges for safe and
effective operation.
Operation mode
Operation range
Cooling
(a)(b)
▪
Outdoor temperature: –10~48°C DB
▪
Indoor temperature: 18~32°C DB
▪
Indoor humidity: ≤80%
Heating
(a)
▪
Outdoor temperature: –15~24°C DB
▪
Indoor temperature: 10~30°C DB
Drying
(a)
▪
Outdoor temperature: –10~48°C DB
▪
Indoor temperature: 18~32°C DB
▪
Indoor humidity: ≤80%
(a)
A safety device might stop the operation of the system if the unit runs outside its
operation range.
(b)
Condensation and water dripping might occur if the unit runs outside its operation range.