TS13-01 Troubleshooting manual
45
L5
Description
IPM error/IGBT error
Supposed Cause
-
Over current due to defective power transistor
-
Over current due to wrong internal wiring
-
Over current due to abnormal supply voltage
-
Over current due to defective PCB
-
Error detection due to defective PCB
-
Over- current due to closed stop valve
-
Over current due to compressor failure
-
Over current due to poor installation condition
-
Connection between main board and IPM board is not properly connect
Troubleshooting
U0
Description
Insufficient gas
Supposed Cause
-
Refrigerant shortage
-
Refrigerant leakage
-
Stop valve closed
-
EXV defective
-
Discharge pipe thermistor defect
-
Indoor and outdoor unit coil thermistor not in actual location or defect