background image

45

When the Need Arises

 

 

 

Troubleshooting

The following table provides brief descriptions of how to handle problems or carry out connection setting. 

 

Refer to the FAQ on our web site for more details.

Wireless LAN connecting adapter

 

„

Call your dealer immediately

 WARNING

When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.

• 

Continued operation in an abnormal condition may result in problems, electric shock or fire.

• 

Consult the dealer where you bought the air conditioner.

Do not attempt to repair or modify the air conditioner by yourself.

• 

Incorrect work may result in electric shock or fire.

• 

Consult the dealer where you bought the air conditioner.

If one of the following symptoms occurs, call your dealer immediately.

• 

The power cord is abnormally hot or damaged.

• 

An abnormal sound is heard during operation.

• 

The circuit breaker, a fuse, or the earth leakage circuit 

breaker cuts off the operation frequently. 

• 

A switch or a button often fails to work properly.

• 

There is a burning smell.

• 

Water leaks from the indoor unit.

Turn off the circuit breaker and call your dealer.

 

„

After a power failure

• 

The air conditioner automatically resumes operation in about 3 minutes. Please wait for a while.

 

„

Lightning

• 

If there is a risk lightning could strike in the neighbourhood, stop operation and turn off the circuit breaker to protect the system.

 

„

Disposal requirements

• 

Dismantling of the unit and handling of the refrigerant, oil and other parts should be done in accordance with the relevant 
local and national regulations.

Wireless LAN connection

When this happens

Explanation and where to check

The device (air conditioner) 

cannot be found on the device  

list screen.

• 

Carry out connection setting again.

• 

Move the router (wireless LAN access point) close to the indoor unit.

• 

There is a possibility that you are using an unsupported smart phone or router 

 

(wireless LAN access point).  For details, refer to the web site.

Even if the wireless LAN 

connecting adapter lamp is lit,  

operation from outside the home 

is not possible.

• 

Communication between the router and the internet connection may not be working. 

 

Please confirm.

The wireless LAN connecting 

adapter lamp does not blink or light.

• 

The wireless LAN connecting adapter is disabled.

• 

Malfunction in communication between the indoor unit and the wireless LAN connecting 
adapter.

• 

There may be a problem with your device. Please contact the store where you bought the air 
conditioner to request a repair service.

None of the above work.

• 

Refer to the FAQ on: 

 

http://www.daikinthai.com/product/dmobile

For instructions about how to operate the DAIKIN Mobile Controller application,
please refer to the operation manual at 

http://www.daikinthai.com/product/dmobile

   

   

 

Содержание FTXM50WVMA

Страница 1: ...Attach the SSID KEY sticker of wireless LAN connecting adapter to the sticker attachment area and keep safe DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXM50WVMA FTXM60WVMA FTXM71WVMA FTKM50W...

Страница 2: ...of the week according to your family s life style The WEEKLY TIMER allows you to set on off times and the desired temperature Page 28 INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement...

Страница 3: ...Basic Operation AUTO DRY COOL HEAT FAN Operation 13 Adjusting the Airflow Rate 15 Adjusting the Airflow Direction 16 Useful Functions MOLD PROOF Operation 17 FLASH STREAMER AIR CLEANING Operation 19...

Страница 4: ...lt in water leakage electric shock or fire hazards Do not use flammable spray near the air conditioner or otherwise fire may result Do not use a refrigerant other than the one indicated on the outdoor...

Страница 5: ...nel may fall and injury or property damage may result Do not locate obstacles in the route The panel may fall and injury or property damage may result Do not bend or damage the wires The wires may be...

Страница 6: ...reen Press this switch once to start operation Press once again to stop it For the operation mode setting refer to the following table Model Mode Temperature setting Airflow rate FTXM50 60 71 AUTO 25...

Страница 7: ...erature sensor back Air inlet back and side Earth terminal inside Refrigerant pipes and inter unit wire Drain hose SSID KEY sticker of wireless LAN connecting adapter Deodorizing filter enzyme blue Wi...

Страница 8: ...om product dmobile compatible Internet line and communicating device Modem router or similar device Wireless LAN access point Application name DAIKIN Mobile Controller free application version 4 0 or...

Страница 9: ...Wireless LAN button POWERFUL button POWERFUL operation Page 23 Wireless LAN button push 5 seconds Wireless LAN connection Page 35 For FTXM50 60 71 ARC466A78 For FTKM50 60 71 ARC466A79 Display LCD Dis...

Страница 10: ...be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET operation Page 24 SWING button and MENU butto...

Страница 11: ...lacing In some cases when battery consumption is accelerated owing usage conditions signal reception may decline before the LCD begins blinking The batteries supplied with the remote controller are fo...

Страница 12: ...day SUN Sunday 3 Press blinks 4 Press to set the clock to the present time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when...

Страница 13: ...ess or and select menu number 3 Press to confirm the selected setting 4 Press or and select the desired brightness BRIGHTNESS Off BRIGHTNESS High default BRIGHTNESS Low 5 Press again Brightness will b...

Страница 14: ...e room by releasing the heat in the room outside Therefore the cooling performance of the air conditioner may be degraded if the outdoor temperature is high Note on DRY operation Eliminates humidity w...

Страница 15: ...erate level helps save energy Recommended temperature setting for cooling 26 0 28 0 C for heating 20 0 24 0 C Cover windows with a blind or a curtain Blocking sunlight and air from outdoors increases...

Страница 16: ...ndoor unit will become quieter In the quiet operation mode the airflow rate is set to a weak level If the temperature dose not reach the desired point change the airflow rate setting If COOL DRY opera...

Страница 17: ...ow direction Press and and appear on the LCD The flaps and louvres move in turn To cancel 3 D airflow press either or again The flaps or louvres will stop moving To set the flaps or louvres at the des...

Страница 18: ...n is enabled appears on the LCD and the MOLD PROOF lamp lights green when MOLD PROOF operation is in progress The STREAMER lamp lights green and flash streamer air cleaning operation starts Display 6...

Страница 19: ...time is short If MOLD PROOF operation does not suit your preference set operation to OFF Page 17 Relation between MOLD PROOF operation and indoor unit lamps Air conditioner MOLD PROOF setting MOLD PRO...

Страница 20: ...e STREAMER lamp lights green and flash streamer air cleaning operation starts Display 6 Press to return to the default screen NOTE What is streamer discharge This is a type of plasma discharge compris...

Страница 21: ...y be difficult to warm up COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL DRY operation and in the downward direction while in HEAT operation which will provide...

Страница 22: ...peration CAUTION Do not place large objects near the INTELLIGENT EYE sensor Also keep heating units and humidifiers outside the sensor s detection area This sensor can detect undesirable objects Do no...

Страница 23: ...LIGENT EYE operation Application range is as follows 90 55 7m 55 Vertical angle 90 Side view Horizontal angle 110 Top view 7m When the air conditioner is function in INTELLIGENT EYE operation if no pe...

Страница 24: ...peration will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximise the coo...

Страница 25: ...ration This operation is performed with lower power and therefore may not provide a sufficient cooling heating effect Pressing causes the settings to be cancelled and disappears from the LCD If the po...

Страница 26: ...s until the time setting reaches the point you like Each pressing of either button increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press...

Страница 27: ...he time setting rapidly 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the...

Страница 28: ...STEP 2 of 24 HOUR ON OFF TIMER Page 25 26 Timer display mode cannot be changed while or are blinking Press or to stop the blinking Display Combining display modes Different display modes 24 HOUR ON O...

Страница 29: ...gs are the same as those for Monday Page 31 6 00 8 30 17 30 22 00 25 0 C 27 0 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for...

Страница 30: ...day 2 Press to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set...

Страница 31: ...D and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Pa...

Страница 32: ...the selected day of the week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the select...

Страница 33: ...witched to setting mode Proceed to Setting mode STEP 4 Page 29 3 Press to exit the confirmation mode appears on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display To...

Страница 34: ...will be activated Reservations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting reservations 1 Press Th...

Страница 35: ...he above website Application software installation Before downloading the application software for installation please read Configuration on Page 7 For Android phones 1 Open Google Play 2 Search using...

Страница 36: ...links briefly The wireless LAN connecting adapter lamp orange blinks for one second 4 Press to return to the default screen To disable 1 While operation is stopped press and hold the button for 5 seco...

Страница 37: ...nnection WPS connection If there is a WPS button on your Wi Fi router please follow the below steps 1 While operation is stopped press and hold the button for 5 seconds appears on the LCD SP menu blin...

Страница 38: ...Sticker on the cover of the manual Sticker on the indoor unit SSID KEY sticker OPERATION MANUAL m Y g d m d 2 Open the DAIKIN Mobile Controller application and select Configure the wireless connectio...

Страница 39: ...aler where you bought the air conditioner The method of cleaning and replacement of the filters may differ depending on the model Refer to the label attached to the separately sold filters themselves...

Страница 40: ...t down 1 Push 2 Pull down 3 Wash the air filters with water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air...

Страница 41: ...et them dry in the shade This filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the filter when removing water from...

Страница 42: ...from the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance...

Страница 43: ...f the air conditioner slightly expand or shrink as a result of temperature changes Whistling sound This sound is generated when refrigerant flows during defrosting operation Clicking sound during oper...

Страница 44: ...progress If this does not suit your preferences set MOLD PROOF to Off The room does not cool down warm up Case Description what to check Air does not come out In HEAT operation The air conditioner is...

Страница 45: ...t is discharged with the airflow We recommend that you have the indoor unit cleaned Please consult your dealer Due to streamer discharge the air outlet may emit a slight odour as trace amounts of ozon...

Страница 46: ...ghtning could strike in the neighbourhood stop operation and turn off the circuit breaker to protect the system Disposal requirements Dismantling of the unit and handling of the refrigerant oil and ot...

Страница 47: ...R TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR CC FAULTY HUMIDITY SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START...

Страница 48: ...The two dimensional bar code is a manufacturing code MODE On Off FAN Temp Mode Swing 3P651499 2 M21N018 2106 HT Quick Reference...