manualshive.com logo in svg
background image

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

 

MODELS

FTXM50PVMA
FTXM60PVMA
FTXM71PVMA

FTKM50PVMA
FTKM60PVMA
FTKM71PVMA

00_CV_3P372379-2B.indd   1

6/30/2014   4:58:36 PM

Содержание FTXM50PVMA

Страница 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXM50PVMA FTXM60PVMA FTXM71PVMA FTKM50PVMA FTKM60PVMA FTKM71PVMA 00_CV_3P372379 2B indd 1 6 30 2014 4 58 36 PM...

Страница 2: ...l of the outdoor unit This function is useful to maintain a quiet neighbourhood Page 18 WEEKLY TIMER Up to 4 timer settings can be saved for each day of the week according to your family s life style...

Страница 3: ...ames of Parts 5 Preparation Before Operation 9 Basic Operation AUTO DRY COOL HEAT FAN Operation 11 Adjusting the Airflow Direction 13 Adjusting the Airflow Rate 14 Useful Functions COMFORT AIRFLOW INT...

Страница 4: ...re hazards Do not use flammable spray near the air conditioner or otherwise fire may result Do not use a refrigerant other than the one indicated on the outdoor unit R32 when installing moving or repa...

Страница 5: ...er with the air conditioner Before cleaning be sure to stop unit operation and turn off the circuit breaker Otherwise an electric shock and injury may result Only connect the air conditioner to the sp...

Страница 6: ...ATION lamp green TIMER lamp orange Page 19 20 23 25 INTELLIGENT EYE lamp green Page 15 Signal receiver Receives signals from the remote controller When the unit receives a signal you will hear a beep...

Страница 7: ...ying filter Outdoor Unit The appearance of the outdoor unit may differ between different models Refrigerant pipes and inter unit wire Earth terminal inside Drain hose Air inlet back and side Air outle...

Страница 8: ...g button Selects the airflow rate setting Page 14 POWERFUL button POWERFUL operation Page 17 HEAT PUMP model ARC466A16 COOLING ONLY model ARC466A14 Display LCD Displays the current settings In this il...

Страница 9: ...n Cancels the timer setting Page 19 20 Cannot be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET...

Страница 10: ...r unit open and close once to set the reference position Position and correctly 2 3 1 Remote controller holder Remote controller Screws NOTE Notes on batteries When replacing the batteries use batteri...

Страница 11: ...punctually To set the clock 1 Press is displayed on the LCD and blink 2 Press to set the current day of the week 3 Press blinks 4 Press to set the clock to the present time Holding down or rapidly inc...

Страница 12: ...on Press again disappears from the LCD The OPERATION lamp goes off AUTO DRY COOL HEAT FAN Operation NOTE Notes on AUTO operation In AUTO operation the system selects an appropriate operation mode COOL...

Страница 13: ...setting For cooling 26 28 C For heating 20 24 C Cover windows with a blind or a curtain Blocking sunlight and air from outdoors increases the cooling heating effect Keep the air filters clean Clogged...

Страница 14: ...aps horizontal blades will begin to swing Right and left airflow direction Press is displayed on the LCD The louvres vertical blades will begin to swing The 3 D airflow direction Press and and are dis...

Страница 15: ...FAN operation DRY operation The airflow rate setting cannot be changed NOTE Note on airflow direction setting The movable range of the flaps varies according to the operation mode Note on 3 D airflow...

Страница 16: ...ensor can detect undesirable objects Do not hit or violently push the INTELLIGENT EYE sensor This can lead to damage and malfunction To start operation Press and select the desired mode Each time is p...

Страница 17: ...f COMFORT AIRFLOW operation and INTELLIGENT EYE operation The airflow rate will be set to AUTO If the up and down airflow direction is selected COMFORT AIRFLOW operation will be canceled Priority is g...

Страница 18: ...rease the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximize the cooling heating effect t...

Страница 19: ...no icon is displayed NOTE Notes on ECONO operation Pressing causes the settings to be cancelled and disappears from the LCD If the power consumption level is already low switching to ECONO operation w...

Страница 20: ...inutes Holding down either button changes the setting rapidly 3 Press again and setting time are displayed on the LCD The TIMER lamp lights orange Display To cancel ON TIMER operation Press and settin...

Страница 21: ...splayed on the LCD The TIMER lamp lights orange Display To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off...

Страница 22: ...ose for Monday Page 24 6 00 8 30 17 30 22 00 25 C 27 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for programmes 1 4 Page 22 8...

Страница 23: ...e per day 2 Press to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will b...

Страница 24: ...operation is activated The TIMER lamp lights orange Display A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Page 24 NOTE Notes on...

Страница 25: ...the week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week...

Страница 26: ...tting mode STEP 4 Page 22 3 Press to exit the confirmation mode is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display To deactivate WEEKLY TIMER operatio...

Страница 27: ...e still other reservations WEEKLY TIMER operation will be activated Reservations for each day of the week This function can be used for deleting reservations for each day of the week It can be used wh...

Страница 28: ...atile liquid such as benzene petrol and thinner Polishing compounds Rough materials such as a scrubbing brush Front panel Wipe it with a soft damp cloth If dirty Page 28 Air filter Vacuum dust or wash...

Страница 29: ...one side 1 Slide 2 Pull Front panel shaft 1 Slide 2 Pull Disconnect the front panel shaft on the other side in the same manner 3 Clean the front panel Wipe it with a soft damp cloth Only neutral deter...

Страница 30: ...d to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then let them dry in the shade Be sure to remove t...

Страница 31: ...rame and attach a new one Do not throw away the filter frame Reuse the filter frame when replacing the titanium apatite photocatalytic air purifying filter When attaching the filter check that the fil...

Страница 32: ...rom the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance...

Страница 33: ...esult of temperature changes Whistling sound This sound is generated when refrigerant flows during defrosting operation Clicking sound during operation or idle time This sound is generated when the re...

Страница 34: ...r does not stop operating Case Description what to check The air conditioner continues operating even after operation is stopped Immediately after the air conditioner is stopped The outdoor unit fan c...

Страница 35: ...r gives off an odour The room odour absorbed in the unit is discharged with the airflow We recommend you to have the indoor unit cleaned Please consult your dealer Others Case Description what to chec...

Страница 36: ...hot or damaged An abnormal sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work pr...

Страница 37: ...FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3...

Страница 38: ...37 Memo 01_EN_3P372379 2B indd 37 6 27 2014 9 26 20 AM...

Страница 39: ...38 01_EN_3P372379 2B indd 38 6 27 2014 9 26 20 AM...

Страница 40: ...3P372379 2B M13B345A 1407 HT The two dimensional bar code is a manufacturing code Quick Reference 00_CV_3P372379 2B indd 2 6 30 2014 4 58 36 PM...

Отзывы: