background image

To delete all reservations

Use this function if you want to delete all reservations for all 
days of the week in one go. This procedure CANNOT be used in 
the setting mode.

1. 

Hold 

 for about 5 seconds while in the default 

display.

Result:

 All reservations will be deleted.

4-7  Wireless LAN connection

If using a remote control PC-board or an interface adaptor for 
DIII-NET, it is necessary to switch the wireless LAN connection 
adapter to OFF.

The user is responsible for providing:

• 

Smartphone, tablet or another smart device with one of the 
following operating systems:

• 

Android 4.0.3 or later

• 

iOS 7.1.2 or later

• 

Internet line and communication device, such as a modem, 
router, etc.

• 

Wireless LAN access point

• 

Installed free 

Daikin Mobile Controller

 application

Note:

 If needed, the SSID number and the KEY are located on 

the unit or can be found in the accessory bag.

a

Label with SSID number and password

4-7-1 

Precautions when using the wireless adapter

Do NOT use near:

• 

Medical equipment.

 E.g. persons using cardiac 

pacemakers or defibrillators. This product may cause 

electromagnetic interference.

• 

Auto-control equipment.

 E.g. automatic doors or fire alarm 

equipment. This product may cause faulty behaviour of the 
equipment.

•  Microwave oven.

 It may affect wireless LAN communications.

4-7-2  To install the Daikin Mobile Controller application

1. 

Open:

• 

Google Play for appliances using Android.

• 

App Store for appliances using iOS.

2. 

Search for Daikin Mobile Controller.

3. 

Follow the directions on the screen to install.

4-7-3 

To set the wireless connection

There are 2 options to connect the wireless adapter with your 
smart device.

•  Connect the wireless adapter to your home network.

  

The wireless adapter will communicate with your smart 
device in your home network using a modem, router or a 
similar device.

•  Connect the wireless adapter to your smart device directly.

For more information and FAQ refer to:

http://www.daikinthai.com/dmobile/index.html

1. 

Stop the operation before setting the wireless connection.

To confirm the wireless adapter connection status

1. 

Hold 

 for at least 5 seconds.

Result: 

The confirmation display (menu 

) appears.

2. 

Press 

 to confirm the selection.

 

Result:

   is blinking.

3. 

Check the indoor unit LED.

…lamp is blinking.

Status

Timer

Communication is OK

Operation and timer

Communication is OFF

4. 

Press 

 to exit the menu.

Result:

 The display will return to the default screen.

To connect the wireless adapter to your home network

The wireless adapter can be connected to your home network 
using the:

• 

WPS

 button on the router (if present).

• 

SSID

 and 

KEY

 number on the unit.

To connect using the WPS button

1. 

Hold 

 for at least 5 seconds in the default screen. 

Result:

 The confirmation display (menu 

 ) appears.

2. 

Press repeatedly 

 or 

 until the WPS setting display 

(menu   ) appears.

 14

01_EN_3P524249-1.indd   14

6/12/2018   1:47:40 PM

Содержание FTXJ25TVMAK

Страница 1: ...round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXJ25TVMAW FTXJ35TVMAW FTXJ50TVMAW FTXJ60TVMAW FTXJ25TVMAK...

Страница 2: ...t panel 17 6 4 To open the front panel 17 6 5 About the air filters 17 6 6 To clean the air filters 18 6 7 To clean the titanium apatite deodorising filter 18 6 8 To close the front panel 18 6 9 To re...

Страница 3: ...ty pipe lightning conductor or telephone earth lead Imperfect earthing may result in electric shock CAUTION Do not use the air conditioner for purposes other than those for which it is intended Do not...

Страница 4: ...e Front panel f Service lid g Intelligent eye sensor h Display i Room temperature and humidity sensor j ON OFF button and operation lamp green k Signal receiver l Timer lamp orange m Intelligent eye l...

Страница 5: ...n is active Operation mode Automatic Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Powerful operation is active Econo operation is active Outdoor unit qui...

Страница 6: ...esulting in battery leakage rupturing or heating Do not damage or peel off labels on the batteries 1 Slide the front cover to take it off 2 Insert 2 dry batteries AAA LR03 alkaline 3 Replace the front...

Страница 7: ...indoor unit position to avoid direct airflow to walls 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu to Result The menu appears on the display blin...

Страница 8: ...a room without heating or cooling Decrease the humidity in a room What The system operates differently depending on the user selection Setting Description Automatic The system cools down or heats up a...

Страница 9: ...up and down swing setting a b a Flap range in cooling or drying operation b Flap range in heating or fan only operation To adjust vertical airflow direction 1 Press Result appears on the LCD The flaps...

Страница 10: ...tically returns to the default screen after 60 seconds To return to the default screen sooner press twice Intelligent eye operation The system detects movement in the room and automatically adjusts th...

Страница 11: ...he outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor...

Страница 12: ...o stop operation press Result and disappear from the LCD and the timer lamp goes off and the day of the week are displayed on the LCD INFORMATION When you set the ON OFF timer the time setting is stor...

Страница 13: ...ock on page 5 INFORMATION Weekly timer and ON OFF timer operation CANNOT be used at the same time The ON OFF timer operation takes priority Weekly timer will be in standby disappears from the LCD When...

Страница 14: ...ons You can confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week an...

Страница 15: ...To install the Daikin Mobile Controller application 1 Open Google Play for appliances using Android App Store for appliances using iOS 2 Search for Daikin Mobile Controller 3 Follow the directions on...

Страница 16: ...he screen 7 Connect your smartphone to the home network To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to switch between th...

Страница 17: ...the unit consumes electricity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running Condensation may form if the humidity is above 80 or if...

Страница 18: ...els off DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the circuit breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean wi...

Страница 19: ...te deodorising filter INFORMATION Clean the filter with water every 6 months 1 Remove the dust from the filter with a vacuum cleaner INFORMATION Replace the filter every 3 years Dispose of the old fil...

Страница 20: ...ance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the user In certain operating conditions the inside of the unit may get dirty after se...

Страница 21: ...lfunction Measure The system operates but heating is insufficient air is NOT blown from the unit To prevent the release of cold air air does not come out directly after operation is started Please wai...

Страница 22: ...flaps louvres or front panel correct their positions at the beginning or end of operation or while operation is stopped It is the sound of the flaps louvres or front panel moving 7 1 9 Symptom White m...

Страница 23: ...http www daikinthai com dmobile index html for more information and FAQ Problem Measure Connection to the WLAN adapter is not possible none of the LEDs are blinking Try operating the unit with the re...

Страница 24: ...3P524249 1 M17B306 1806 HT The two dimensional bar code is a manufacturing code...

Отзывы: