NIGHT SET Mode
Outline
When the OFF TIMER is set, NIGHT SET Mode is automatically activated. NIGHT SET Mode
keeps the airflow rate setting.
Detail
NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in
the case of heating. This prevents excessive cooling in summer and excessive heating in winter
to ensure comfortable sleeping conditions, and also conserves electricity.
<Cooling>
<Heating>
1.10 ECONO Operation
Outline
ECONO operation reduces the maximum operating current and the power consumption.
This operation is particularly convenient for energy-saving. It is also a major bonus when
breaker capacity does not allow the use of multiple electrical devices and air conditioners.
It can be easily activated by pushing the
ECONO
button on the wireless remote controller.
Detail
When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in cool or dry
operation. This function can only be set when the unit is running. Pressing the
ON/OFF
button on the remote controller cancels the function.
This function and POWERFUL operation cannot be used at the same time. The latest
command has the priority.
(R18917)
TIMER operation
NIGHT SET Mode ON
Target temperature
+0.5˚C
temperature shift
Operation stops
at the set hours
0.5˚C
1 hour
TIMER operation
NIGHT SET Mode ON
Target temperature
–2˚C
temperature shift
1 hour
2˚C
(R19386)
ECONO Operation
(R19427)
Normal operation
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current
Содержание FTXG20LV1BW
Страница 12: ...SiBE041401E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Страница 14: ...SiBE041401E 3 Specifications Part 2 Specifications 1 Specifications 4...
Страница 60: ...SiBE041401E 49 Remote Controller Part 5 Remote Controller 1 Remote controller 50...
Страница 113: ...SiBE041401E Check Service Diagnosis 102 50 class Diode bridge R19944...
Страница 127: ...Revision History Month Year Version Revised contents 03 2014 SiBE041401E First edition...