4 Operation

Operation manual

6

FTXF20~71A2V1B

Daikin room air conditioner

3P511999-3 – 2017.11

4.3.3

Airflow direction

When.

 Adjust the airflow direction as desired.

What.

  The  system  directs  the  airflow  differently,  depending  on  the

user selection (swinging or fixed position). It does so by moving the
vertical blades.

Setting

Airflow direction

 Vertical auto swing

Moves up and down.

[—]

Stays in a fixed position.

CAUTION

▪ ALWAYS  use  a  user  interface  to  adjust  the  angles  of

the  flap.  When  the  flap  is  swinging  and  you  move  it
forcibly by hand, the mechanism will break.

▪ Be  careful  when  adjusting  the  louvers.  Inside  the  air

outlet, a fan is rotating at high speed.

Note:

  The  movable  range  of  the  flap  varies  according  to  the

operation  mode.  The  flap  will  stop  at  the  upper  position  when  the
airflow rate is changed to low during the up and down swing setting.

a

b

c

a

Flap range in cooling or drying operation

b

Flap range in heating operation

c

Flap range in fan only operation

To adjust the airflow direction

1

To use auto swing, press 

.

Result: 

 will appear on the LCD.

Result: 

The flap (horizontal blade) will begin to swing.

2

To  use  fixed  position,  press 

  when  the  flap  reaches  the

desired position.

Result: 

 disappears from the LCD.

To adjust the louvers (vertical blades)

1

Hold 1 or both knobs and move the louvers.

a

a

a

Knobs

INFORMATION

When  the  unit  is  installed  in  a  corner  of  a  room,  the
direction  of  the  louvers  should  be  facing  away  from  the
wall. Efficiency will drop if a wall blocks the air.

4.3.4

Comfort airflow operation

This operation can be used in 

Heating

 or 

Cooling

 operation mode.

It will provide a comfortable wind that will NOT come in direct contact
with people.

To start/stop Comfort airflow operation

INFORMATION

Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If  the  upper  or  lower  direction  is  selected,  Comfort  airflow
operation will be cancelled.

1

Press 

 to start.

Result: 

The  flap  position  will  change, 

  is  displayed  on  the

LCD, and the airflow rate is set to automatic.

Mode

Position of flap…

Cooling/Drying

Up

Heating

Down

2

Press 

 to stop.

Result: 

The  flap  will  return  to  the  position  from  before  the  Comfort

airflow mode; 

 disappears from the LCD.

4.3.5

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

To start/stop Powerful operation

1

Press 

 to start.

Result: 

  is  displayed  on  the  LCD.  Powerful  operation  runs

for 20 minutes; after that, operation returns to the previously set
mode.

Mode

Airflow rate

Cooling/Heating/Automatic

▪ To  maximize  the  cooling/

heating  effect,  the  capacity  of
outdoor unit is increased.

▪ The  airflow  rate  is  fixed  to  the

maximum setting.

The temperature and airflow
settings CANNOT be changed.

Drying

▪ The  temperature  setting  is

lowered by 2.5°C.

▪ The  airflow  rate  is  slightly

increased.

Fan only

The airflow rate is fixed to the
maximum setting.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

INFORMATION

Powerful operation CANNOT be used together with Econo
and  Comfort  airflow  operation.  The  last  selected  function
takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

Содержание FTXF20A2V1B

Страница 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20A2V1B FTXF25A2V1B FTXF35A2V1B FTXF50A2V1B FTXF60A2V1B FTXF71A2V1B...

Страница 2: ...t Please Keep the documentation for future reference Target audience End users INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or f...

Страница 3: ...ed if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your installer...

Страница 4: ...the back cover 2 Insert both batteries at once 3 Replace the back cover 2 3 1 AAA LR03 3 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and cl...

Страница 5: ...nfo Outside temperature The system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor...

Страница 6: ...operation This operation can be used in Heating or Cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people To start stop Comfort airflow operation I...

Страница 7: ...imer lamp goes off INFORMATION Program the timer again in case of A breaker has turned the unit off A power failure After replacing batteries in the user interface To start stop OFF timer operation 1...

Страница 8: ...ervice The installer has to perform a yearly maintenance About the refrigerant This product contains fluorinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warm...

Страница 9: ...erating the unit with dirty filters means that the filter CANNOT deodorize the air CANNOT clean the air poor heating cooling causes odour 6 5 To clean the air filters 1 Open the front panel 2 Push the...

Страница 10: ...airflow rate setting Refer to 4 3 2 Airflow rate on page 5 Check the temperature setting Refer to 4 3 1 To start stop operation and to set the temperature on page 5 Check if the airflow direction sett...

Страница 11: ...the service manual Fault diagnosis by user interface The user interface can receive an error code from the indoor unit referring to the fault It is important to understand the problem and take measur...

Страница 12: ...3P511999 3 2017 11 Copyright 2017 Daikin...

Отзывы: