Check
SiBE041010EA
93
Service Diagnosis
5.13 Power Module Check
Check No.22
Note:
Make sure that the voltage between (+) and (–) of the power module is approximately 0 V
before checking.
Disconnect the compressor harness connector from the outdoor unit PCB. To disengage the
connector, press the protrusion on the connector.
Follow the procedure below to measure resistance between the terminals of the power
module and the terminals of the compressor with a multi-tester. Evaluate the measurement
results referring to the following table.
Negative (–) terminal of
tester (positive terminal
(+) for digital tester)
Power module
(+)
UVW
Power module
(–)
UVW
Positive (+) terminal of
tester (negative terminal
(–) for digital tester)
UVW
Power module
(+)
UVW
Power module
(–)
Resistance is OK.
several k
Ω
~ several M
Ω
Resistance is NG.
0
Ω
or
∞
(R19121)
Power module