1-16
ELECTRICAL WIRING CONNECTION
09/12 class
[Method of mounting conduit]
●
A protection plate is fixed for protection from the high-voltage section.
1) Dismount the stop valve cover by removing the screw.
2) Dismount the protection plate by removing the 2 screws.
3) Dismount the conduit mounting cover by removing the 2 screws.
4) Pass wires through the conduit and secure them with a lock nut.
5) After completing the work, reattach the stop valve cover, the conduit mounting cover, and the protection plate to its
original position.
SIG
Power supply
terminal block
Protection plate
Screws
Screws
Conduit
Lock nut
Conduit
mounting
cover
Conduit
mounting
cover
Shape wires so
that the proctection
plate and conduit
mounting plate fit
securely.
L1
L2
18/24 class
[Method of mounting conduit]
1) Dismount the service lid by removing the screws.
2) Pass wires through the conduit and secure them with a lock nut.
3) After completing the work, reattach the service lid to its original position.
Power supply
terminal block
Screws
Conduit
Lock nut
Service lid
Shape wires so
that the proctection
plate and conduit
mounting plate fit
securely.
L1
L2
01_IM-BMS-FTX&FTK_EN.indb 16
01_IM-BMS-FTX&FTK_EN.indb 16
2/28/2020 6:27:18 PM
2/28/2020 6:27:18 PM
Содержание FTX09AXVJU
Страница 2: ...01_IM BMS FTX FTK_EN indb 2 01_IM BMS FTX FTK_EN indb 2 2 28 2020 6 27 13 PM 2 28 2020 6 27 13 PM ...
Страница 22: ...MEMO 01_IM BMS FTX FTK_EN indb 20 01_IM BMS FTX FTK_EN indb 20 2 28 2020 6 27 19 PM 2 28 2020 6 27 19 PM ...
Страница 42: ...MEMORÁNDUM 02_IM BMS FTX FTK_ES indb 20 02_IM BMS FTX FTK_ES indb 20 2 28 2020 6 32 44 PM 2 28 2020 6 32 44 PM ...
Страница 62: ...LE MÉMO 03_IM BMS FTX FTK_FR indb 20 03_IM BMS FTX FTK_FR indb 20 2 28 2020 6 35 02 PM 2 28 2020 6 35 02 PM ...
Страница 63: ...01_IM BMS FTX FTK_EN indb 21 01_IM BMS FTX FTK_EN indb 21 2 28 2020 6 27 19 PM 2 28 2020 6 27 19 PM ...