background image

3

8

• Split - Sky Air • FTX-J3

11

• Indoor Unit • FTX-J3

8

Sound data

8 - 1

Sound Pressure Spectrum

1

.

2

.

3

.

4

.

5

.

41

27

41

29

Location

of

microphone

B

A

Scale

dBA

=

A

Ͳ

weighted

sound

pressure

level

(A

scale

according

to

IEC).

Octave

band

centre

frequency

[Hz]

Cooling

mode

Sound

pressure

level

[dB]

Sound

pressure

level

[dB]

Heating

mode

Legend

Octave

band

centre

frequency

[Hz]

Notes

Cooling

Heating

dBA

A

B

dBA

A

B

Total

dB

Total

dB

FTX35J3

Background

noise

already

taken

into

account.

Operating

conditions:

power

source

220

Ͳ

240

V/220

V

50/60

Hz;

JIS

standard

The

operation

noise

measuring

method

is

in

accordance

with

JISC9612.

Measuring

location:

anechoic

chamber

Operating

noise

varies

depending

on

operation

and

ambient

conditions.

C

C

B

NR0

NR5

NR10

NR15

NR20

NR25

NR30

NR35

NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

NR80

NR85

NR90

10

20

30

40

50

60

70

80

90

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

63

125

250

500

1000

2000

4000

8000

dBA

NR0

NR5

NR10

NR15

NR20

NR25

NR30

NR35

NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

NR80

NR85

NR90

10

20

30

40

50

60

70

80

90

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

63

125

250

500

1000 2000 4000 8000

dBA

3D092113

Содержание FTX-J3

Страница 1: ...Air Conditioning Technical Data Wall mounted unit EEDEN15 100 FTX J3...

Страница 2: ......

Страница 3: ...J3 1 Features 2 2 Specifications 3 Technical Specifications 3 Electrical Specifications 4 3 Options 5 4 Dimensional drawings 6 5 Centre of gravity 7 6 Piping diagrams 8 7 Wiring diagrams 9 Wiring Dia...

Страница 4: ...he discharge flaps up and down for efficient air and temperature distribution throughout the room Indoor unit silent operation silent button on the remote control lowers the operation sound of the ind...

Страница 5: ...272 Low m min 5 9 6 0 6 1 cfm 208 212 215 Silent operati on m min 4 7 4 8 4 9 cfm 166 169 173 Heating High m min 9 4 9 7 10 1 cfm 331 342 356 Nom m min 7 8 8 0 8 4 cfm 276 283 295 Low m min 6 3 6 7 cf...

Страница 6: ...patite photocatalytic air purification filter Quantity 2 Standard Accessories Indoor unit fixing screws Quantity 2 Notes SL The silent fan level of the air flow rate setting Piping connections Liquid...

Страница 7: ...3 3 Split Sky Air FTX J3 5 Indoor Unit FTX J3 3 Options 3 1 Options...

Страница 8: ...RI WKH XQLW 1DPHSODWH QFOXGLQJ PRXQWLQJ SODWH 1DPHSODWH ODS RWWRP VLGH 6LJQDO UHFHLYHU 2SHUDWLRQ ODPS 7LPHU ODPS QGRRU XQLW 2Q 2 VZLWFK 5RRP WHPSHUDWXUH VHQVRU RFDWHG LQVLGH RI WKH XQLW URQW SDQHO IL...

Страница 9: ...3 5 Split Sky Air FTX J3 7 Indoor Unit FTX J3 5 Centre of gravity 5 1 Centre of Gravity 7...

Страница 10: ...3 6 Split Sky Air FTX J3 8 6 Piping diagrams 6 1 Piping Diagrams X7 X7 X7 X7 X7 X7 X7 X7 QGRRU XQLW HDW H FKDQJHU 7KHUPLVWRU KHDW H FKDQJHU DQ PRWRU LHOG SLSLQJ LHOG SLSLQJ 5HIULJHUDQW IORZ RROLQJ HDW...

Страница 11: ...3 7 Split Sky Air FTX J3 9 Indoor Unit FTX J3 7 Wiring diagrams 7 1 Wiring Diagrams Single Phase...

Страница 12: ...5 NR80 NR85 NR90 10 20 30 40 50 60 70 80 90 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 63 125 250 500 1000 2000 4000 8000 dBA 3D092111 s 1 2 3 4 5 40 26 40 28 Location of microphone B A Scale...

Страница 13: ...onditions power source 220 240 V 220 V 50 60 Hz JIS standard The operation noise measuring method is in accordance with JISC9612 Measuring location anechoic chamber Operating noise varies depending on...

Страница 14: ......

Страница 15: ...in Europe N V has compiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy re liability or fitness for particular purpose...

Отзывы: