background image

English 

2

After reading, keep this manual in a conve-

• 

nient place so that you can refer to it when-
ever necessary. If the equipment is trans-
ferred to a new user, be sure also to hand 
over the manual.

Meanings of 

DANGER

WARNING

CAUTION

, and 

NOTE

 Symbols:

 DANGER

 .......... Indicates an imminently haz-

ardous situation which, if not 
avoided, will result in death or 
serious injury.

 WARNING

 ........ Indicates a potentially hazard-

ous situation which, if not 
avoided, could result in death 
or serious injury.

 CAUTION

 ......... Indicates a potentially hazard-

ous situation which, if not avoid-
ed, may result in minor or mod-
erate injury. It may also be used 
to alert against unsafe practices.

 NOTE

 ................ Indicates situations that may 

result in equipment or proper-
ty-damage accidents only.

 DANGER

Do not install the unit in an area where fl am-

• 

mable materials are present due to risk of 
explosion resulting in serious injury or death.

Any abnormalities in the operation of the air 

• 

conditioner or heat pump such as smoke or 
fi re, could result in severe injury or death. 
Turn off the power and contact your dealer 
immediately.

Refrigerant gas may produce toxic gas if it 

• 

come in contact with fi re, such as from a fan, 
heater, stove, or cooking device. Exposure to 
this gas could cause severe injury or death.

Consult your local dealer regarding modifi ca-

• 

tion, repair and maintenance of the air condi-
tioner.
Improper workmanship may result in water 
leakage, electric shocks or fi re hazards.

For refrigerant leakage, consult your dealer. 

• 

Refrigerant gas is heavier than air and re-
places oxygen. A massive leak could lead to 
oxygen depletion, especially in basements, 
and an asphyxiation hazard could occur lead-
ing to serious injury or death.

If equipment utilizing a burner is used in the 

• 

same room as the air conditioner or heat 
pump, there is the danger of oxygen defi cien-
cy which could lead to an asphyxiation haz-
ard resulting in serious injury or death. Be 
sure to ventilate the room suffi ciently to 
avoid this hazard.

Safely dispose of the packing materials. 

• 

Packing materials, such as nails and other 
metal or wooden parts, may cause stabs or 
other injuries.

Tear apart and throw away plastic packaging 

• 

bags so that children will not play with them. 
Children playing with plastic bags face the 
danger of death by suffocation.

Do not install the air conditioner at any place 

 

where there is a danger of fl ammable gas 
leakage.
In the event of a gas leakage, build-up of gas 
near the air conditioner may result in fi re haz-
ards.

 WARNING

Contact your dealer for repair and mainte-

• 

nance. Improper repair and maintenance may 
result in  water leakage, electric shock, and 
fi re. Only use accessories made by Daikin 
that are specifi cally designed for use with the 
equipment and have them installed by a pro-
fessional.

Contact your dealer to move and reinstall the 

• 

air conditioner or heat pump. Incomplete 
installation may result in  water leakage, elec-
tric shock, and fi re.

Never let the indoor unit or the remote con-

• 

troller get wet. Water can cause an electric 
shock or a fi re.

Never use fl ammable spray such as hair 

• 

spray, lacquer, or paint near the unit. Flam-
mable spray may cause a fi re.

When a fuse blows out, never replace it with 

• 

one of incorrect ampere ratings or different 
wires. Always replace any blown fuse with a 
fuse of the same specifi cation.

Never remove the fan guard of the unit. A fan 

• 

rotating at high speed without the fan guard 
is very dangerous.

Never inspect or service the unit by yourself. 

• 

Contact a qualifi ed service person to perform 
this work.

01_EN_3P250362-4B.indd   2

01_EN_3P250362-4B.indd   2

1/5/2012   2:56:51 PM

1/5/2012   2:56:51 PM

Содержание FTQ18PBVJU

Страница 1: ...with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre donn au propri taire de l quipement Le...

Страница 2: ...f a j d k i d b f k e Set to Cool Heat 74F 70F Auto This function is not available CENTRAL CONTROL MASTER CONTROLLED SETBACK STANDBY Standard display example 2 1 8 10 6 7 3 4 5 9 3 2 00_CV_3P250362 4...

Страница 3: ...the following control system type Two remote controllers control system Two remote controllers control one indoor unit The unit is individually operated NOTE Contact your dealer in case of two remote...

Страница 4: ...t utilizing a burner is used in the same room as the air conditioner or heat pump there is the danger of oxygen deficien cy which could lead to an asphyxiation haz ard resulting in serious injury or d...

Страница 5: ...rm if the humidity is above 80 or if the drain outlet gets blocked Before cleaning stop the operation of the unit by turning the power off or by pulling the supply cord out from its receptacle Other w...

Страница 6: ...uces elec tromagnetic waves h Places with an acid or alkaline mist i Places where fallen leaves can accumulate or where weeds can grow Take snow protection measures Contact your dealer for the details...

Страница 7: ...this air conditioner or heat pump and that all electrical work is car ried out by qualified personnel according to local laws and regulations Pay attention to the installation location Are the followi...

Страница 8: ...cur rently selected item Display contents are changed to previous screen per page On Off button 8 Press once to operate and press once again to stop Operation lamp 9 Green lamp lights up during operat...

Страница 9: ...lains the sequence of operation for the remote controller Operate the buttons according to the procedure Operation button display Displays the location of buttons to be operated Setting Main Menu Air...

Страница 10: ...ive minutes for the condensate pump to finishing draining residual water from the unit CHARACTERISTICS OF HEAT MODE The system automatically controls the follow ing operating modes to prevent the redu...

Страница 11: ...lled by the master in 9 door unit Setback 10 Please refer to attached manual with remote con troller for another operation OPTIMUM OPERATION 7 Observe the following precautions to ensure the system op...

Страница 12: ...e air conditioner or heat pump If the area around the indoor unit is very dusty use a dust proof cover local procurement Cleaning the inside of the indoor unit It is necessary to clean the inside of t...

Страница 13: ...tlet are not blocked Remove any obstacle Check if the ground is connected Might there be a broken wire somewhere Contact your dealer if there are any problems Clean the air filter After cleaning the a...

Страница 14: ...less of the remote controller indication WHITE MIST COMES OUT OF A UNIT III When humidity is high during cooling op eration In oily or dusty places If the inside of an indoor unit is extremely con tam...

Страница 15: ...case and none of the other mentioned malfunctions are evident investigate the system accord ing to the following procedures If the system does not operate at all 1 Check if there is a power failure W...

Страница 16: ...e curtains or blinds When there are too many inhabitants in the room when cooling Cooling effect decreases if heat gain of the room is too large The heat source of the room is excessive when cooling C...

Страница 17: ...3P250362 4B EM11A010 1201 HT 00_CV_3P250362 4B indd 2 00_CV_3P250362 4B indd 2 1 17 2012 9 39 37 AM 1 17 2012 9 39 37 AM...

Отзывы: