RZQ
EDUS281008
64
Detail information of options
Installation
C : 3K07319A
Use pliers to bull and attach
INSTALLATION
1. For seam jointed-roofs, attach and fix the folded-plate
clamp to the roof and then attach the attachment
plate (2) to the clamp as shown in the figure.
2. For layered folded-plate roofs, place attachement
plate (2) onto the roof’s bolt nut and then follow the same
procedure as in Step 1.
3. Use the plate screws to place attachment plate (1) onto
the outdoor unit as shown in figure.
If there are no plate screws on the front and back outdoor
unit top plate, align the screw hole of the attachment
plate (1) and open a 1/8” diameter hold in the plate.
Then use the included tapping screws to attach attachment plate (1).
4. To install the wire ropes, follow the wire rope attachment
procedure on the back side of these instructions to ensure
proper attachment of ropes on both sides of the outdoor unit
in 4 places.
Folded-plate roof
(Seam jointed)
Outdoor unit top plate
Attachment
plates
Overturn prevention
support KYZP15C
Attachment plates (1)(2)
Wire rope
Clamp
Bulls
Outdoor
unit
Folded-plate clamp
Folded-plate roof
installation base
Outdoor unit fixture Folded-plate roof fixture
Outdoor unit
Tapping screw
Attachment
plates (1)
Outdoor unit top plate
Wire rope
Wire rope
Folded-plate
roof
(Seam jointed)
Clamp
For seam-jointed roofs
Attachment
plate (2)
Folded plate clamp
view
Wire rope attachment procedure
Folded-plate roof fixutre
Attachment plate (2)
Clamp
Adjustment pin
Wire rope
Содержание FTQ-PA
Страница 1: ...EDUS281008 Split System Air Conditioners Air Handling Unit FTQ PA RZQ P9 ...
Страница 12: ...EDUS281008 Dimensions and service space FTQ PA RZQ P 9 1 3D06421 ...
Страница 15: ...Piping diagrams EDUS281008 12 FTQ PA RZQ P 5 2 Outdoor unit RZQ18PVJU9 RZQ24PVJU9 3D062238B ...
Страница 17: ...Wiring diagrams EDUS281008 14 FTQ PA RZQ P 6 2 Outdoor unit RZQ18PVJU9 RZQ24PVJU9 3D062307B GROUND GROUND ...
Страница 18: ...EDUS281008 Wiring diagrams FTQ PA RZQ P 15 1 6 3 External connection diagram RZQ18PVJU9 RZQ24PVJU9 3D064230 ...
Страница 20: ...EDUS281008 Electrical characteristics FTQ PA RZQ P 17 1 7 2 Electric heater ...
Страница 24: ...EDUS281008 Capacity tables FTQ PA RZQ P 21 1 9 2 Capacity correction ratio RZQ18PVJU9 RZQ24PVJU9 C 3D064228A ...
Страница 25: ...Operation limits EDUS281008 22 FTQ PA RZQ P 10 Operation limits RZQ18PVJU9 RZQ24PVJU9 3D064229 ...