Removal of PCBs (Pattern 1)
Si041049
14
Removal Procedure
6. Removal of PCBs (Pattern 1)
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the shield plate.
Preparation
Remove the electrical box
according to the “Removal of
Electrical Box”.
1
The figure shows the
appearance of the
electrical box.
2
Unfasten the hooks at
the upper 2 positions of
the shield plate.
3
Unfasten the hook at
the side of the shield
plate.
4
Lift up the shield plate
to unfasten the lower
hooks and remove it.
(R13747)
Signal receiver PCB
Control PCB
Shield plate
INTELLIGENT EYE
sensor PCB
Display PCB
(inside)
(R8085)
Hook
Hook
(R10619)
Shield plate
Hook (side)
Hook (lower)