Fan Motor (Without Removing Indoor Heat Exchanger)
Si041352EB
22
Removal Procedure
5
Remove the fan motor
fixing plate (lower).
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
(1) Insert the fan motor with
approx. 5 mm (0.2 inch) left.
(2) Tighten the screw until it
stops. Then give the screw
one more turn.
(3) Rotate the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(5) If not appropriate, go back to
(1).
6
Remove the fan motor.
7
Remove the vibration
absorber.
When reassembling, engage
the vibration absorber
completely.
Step
Procedure
Points
(R9564)
5 mm (0.2 inch)
Side face of rotor
(R18879)
Side face of
bottom frame
(R9582)
(R9565)
Fan motor
(R9567)
(R9566)
Vibration
absorber