Detach the
filter element
and attach a
new one.

Set the air
filters as they
were and
close the front
grille.

(Push the grille
at the 4 points,
two at both sides
and in the
middle.)

5

Air filter

Air purifying

filter frame

• 

Hold the recessed 
parts of the frame 
and unhook the four 
claws.

1

3

2

Open the front grille and pull out
the air filters.

Take off the air
purifying filters.

Wipe them with dry soft cloth.
For cleaning, do not use water hotter than
40°C, benzine, gasoline, thinner, nor other
volatile oils, polishing compound, scrubbing
brushes nor other hard stuff.

(It is recommended to replace them every
three months.)

Air purifying filters need to be replaced regularly.

Attach the air
purifying filter.

Care and Cleaning

NOTE

To order air purifying filters, contact the
service shop where you bought the air
conditioner.

Once the air purifying filter element gets
dirty, it is not reusable but must be thrown
away.

Operation with dirty air purifying filters :
• cannot clean the air.
• results in poor cooling and heating.
• may cause odour.

Cleaning the indoor and outdoor
units and the remote controller

Replacing air purifying filters

Item

Air purifying filter (with frame)
Air purifying filter (without frame)

Part No.

KAF918A41
KAF918A42

4

Push

Before cleaning, be sure to stop the 
operation and turn the breaker OFF.

(It is recommended to clean them every two weeks.)

1

Open the front grille.

2

Push cleaning lamp 
reset button. 

(See page 5.)

3

Pull out the air filters.

4

Take off the air 
purifying filters and 
clean them.

5

Set the air purifying filters and the air filters 
as they were and close the front grille.

CAUTION

Cleaning the air filters

Clean the air filters, 
when cleaning lamp 
lights up.

Hold the grille by the tabs on the two sides 
and lift it unitl it stops with a click. (about 60

°

)

Push a little upwards the 
tab at the center of each 
air filter, the pull it down.

Wash them with 
water, or clean 
them with a 
vacuum cleaner.
If the dust does not 
come off easily, wash them with neutral 
detergent thinned with lukewarm water, 
then dry them up in the shade.

Insert claws of the filters into slots of the front panel. The 
front grille should lock at both sides and at the point in 
the middle. Push the grille at the 4 points indicated by    .

In a dusty environment, clean the air filters at 
least once in every two weeks even before the 
CLEANING lamp lights up.
Operation with dusty air filters lowers the cooling 
and heating capacity and wastes energy.

NOTE

Содержание FT50GAVAL

Страница 1: ...FT50GAVAL FTY50GAVAL FT60GAVAL FTY60GAVAL MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual ENGLISH PORTUGUES ESPA OL...

Страница 2: ...blade flap 10 Adjusting the vertical blade louvre 10 POWERFUL Operation 11 Timer Operation OFF TIMER operation 12 ON TIMER operation 12 CARE Care and Cleaning Cleaning the air filters 13 Cleaning the...

Страница 3: ...ight accompany addition of refrigerant The refrigerant used in the air conditioner is safe Although leaks should not occur if for some reason any refrigerant happens to leak into the room make sure it...

Страница 4: ...the unit or a qualified technician The air conditioner must be earthed Incomplete earthing may result in electric shocks Do not connect the earth line to a gas pipe water pipe lightening rod or a tel...

Страница 5: ...must be discharged to a place of good drainage Installation site For installation choose a place as described below A place solid enough to bear the weight of the unit which does not amplify the opera...

Страница 6: ...ON Receiver FT COOL Mode 22 C Temperature setting AUTO FTY AUTO 25 C AUTO Air flow rate Control panel Cleaning lamp reset button Push this button to turn the CLEANING lamp off DAIKIN Front grille Indi...

Страница 7: ...w rate setting SWING buttons See page 10 It changes the temperature or time setting Display It displays the current settings In this illustration each section is shown with all its displays ON for the...

Страница 8: ...t drop the remote controller Do not get it wet The maximum distance for communication is about 7 m ATTENTION Remote controller holder Set Push 1 2 To fix the remote controller holder on the wall Choos...

Страница 9: ...C Indoor temperature 28 C max Outdoor temperature 19 to 54 C Indoor temperature 18 to 32 C Indoor humidity 80 max If operation is continued out of this range A safety device may work to stop the opera...

Страница 10: ...r conditioner heats the room by taking heat from outdoor air to indoors the heating capacity becomes smaller in lower outdoor temperatures If the heating effect is insufficient it is recommended to us...

Страница 11: ...m the display of remote controller DRY COOL FAN HEAT ATTENTION Always use a remote controller to adjust the flap angle If you attempt to move it forcibly with hand when it is swinging the mechanism ma...

Страница 12: ...ration During you use POWERFUL operation the other functions will not go on Press To cancel POWERFUL operation POWERFUL Operation 1 Press Notes on POWERFUL operation In COOL and HEAT mode To maximize...

Страница 13: ...et the clock to the present time See page 8 NIGHT SET MODE When the OFF TIMER is set the air conditioner automatically adjusts the temperature setting 0 5 C up in COOL 2 0 C down in HEAT to prevent ex...

Страница 14: ...ilters Item Air purifying filter with frame Air purifying filter without frame Part No KAF918A41 KAF918A42 4 Push Before cleaning be sure to stop the operation and turn the breaker OFF It is recommend...

Страница 15: ...tuff After cleaning make sure that the front grille is securely fixed 1 3 2 4 Attach the front grille Set the 3 keys of the front grille into the slots and push them in all the way Supporting the fron...

Страница 16: ...system is taking away the frost on the outdoor unit You should wait for about 3 to 10 minutes In HEAT mode The frost on the outdoor unit melts into water or steam when the air conditioner is in defro...

Страница 17: ...d the outdoor units Is the temperature setting appropriate Are the windows and doors closed Are the air flow rate and the air direction set appropriately Are the air filters clean Is there anything to...

Страница 18: ...use or the earth leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and...

Страница 19: ...HAILAND DAIKIN INDUSTRIES THAILAND LTD DAIKIN INDUSTRIES THAILAND LTD INDOOR UNIT OUTDOOR UNIT RATED VOLTAGE RATED FREQUENCY COOLING POWER INPUT RATING CURRENT INPUT RAITING CAPACITY HEATING POWER INP...

Страница 20: ...3P062628 9N M00B043F 0601 HT...

Отзывы: