2
English
ACCESSORIES
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the shut-off valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into
refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
• Only handle the indoor unit with gloves.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial and household use by lay persons.
• Sound pressure level is less than 70 dB (A).
Insulation
for fitting
Screws for
duct flanges
Washer
fixing plate
Clamp
Sealing
material
Drain hose
Washer for
hanging bracket
Sealing pad
Clamp metal
Air filter
Leveling screws
for liquid pipe
for gas pipe
Small
Large
[ Other ]
• Installation
manual
• Operation
manual
1 set
1 set
6 pcs.
2 pcs.
8 pcs.
4 pcs.
24 pcs.
Large and small
1 each
1 each
1 pc.
1 pc.
1 pc.
1 set
Optional accessories
・
This indoor unit requires one of the remote controllers listed below.
・
There are two types of remote controller: wired and wireless.
Select a remote controller according to customer’s request and install in an
appropriate place
Refer to the table below for selecting a suitable remote controller:
4x M6
Remote controller
wired remote controller
wireless remote controller
BRC1D52/BRC1D61/BRC1E51A/BRC2E52C7
BRC1E52A/BRC1E52B/BRC3E52C7
BRC4C65
Содержание FNQ25A2VEB
Страница 1: ...INSTALLATION MANUAL FNQ25A2VEB FNQ35A2VEB FNQ50A2VEB FNQ60A2VEB R410A Split series ...
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ...4P393317 1 2014 12 Copyright 2014 Daikin ...