3
English
Do not allow a child to mount on the outdoor
unit or avoid placing any object on it.
Falling or tumbling may result in injury.
Do not expose animals and plants directly to
the wind.
Adverse influence to animals and plants may
result.
Do not wash the air conditioner with water.
Electric shock or fire may result.
Do not install the air conditioner at any place
where flammable gas may leak out.
If the gas leaks out and stays around the air con-
ditioner, a fire may break out.
Execute complete drain piping for perfect
drainage.
Incomplete piping may result in a water leakage.
The appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to
ensure that they do not play with the appli-
ance.
Consult with installation contractor for
cleaning the inside of the air conditioner.
Wrong cleaning may make the plastics parts
broken or cause failure of water leakage or elec-
tric shock.
Do not touch the air inlet or aluminium fin of
the air conditioner.
Otherwise, injury may be caused.
Do not place objects in direct proximity of
the outdoor unit and do not let leaves and
other debris accumulate around the unit.
Leaves are a hotbed for small animals which can
enter the unit. Once in the unit, such animals can
cause malfunctions, smoke or fire when making
contact with electrical parts.
If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
3. OPERATION RANGE
OUTDOOR
UNIT
INDOOR
OUTDOOR
TEMPERA-
TURE
RZP71
DV1/VAL
RZP100
DV1/VAL
RZP125
DV1/TAL
RZP140
DTAL
TEMPERA-
TURE
HUMID-
ITY
D
B
21 to 35
80% or
below
D
B
–5 to 50
W
B
14 to 25
HEATING
D
B: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote con-
troller is 16°C to 32°C.
Regarding places for installation
• Is the air conditioner installed at a well-ventilated
place where there are no obstacles around?
• Do not use the air conditioner in the following
places.
a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring
resort
d. Where there are considerable voltage fluctua-
tions such as a factory or plant
e. Vehicles and vessels
f. Where there is much spray of oil and vapor
such as a cookery, etc.
g. Where there are machines generating electro-
magnetic waves
h. Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer.
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
• Make sure that a separate power supply circuit
is provided for this air conditioner and that all
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.
Pay attention to running noises, too
• Are the following places selected?
a. A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b. A place where the hot wind discharged from the air
outlet of the outdoor unit and the running noises.
OUTDOOR
UNIT
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
RZP71
DV1/VAL
RZP100
DV1/VAL
RZP125
DV1/TAL
RZP140
DTAL
D
B
15 to 27
D
B
–14 to 21
W
B
–15 to 15.5
4. INSTALLATION SITE