Страница 1: ...DAIKIN SASO Part No R08019037002 MODELS FHC20JEVLK RD20JEVLK FHC25JEVLK RD25JEVLK FHC30JEVLK RD30JEVLK FHC40JEVLK RD40JEVLK FHC50JEVLK RD50JETLK FHYC20JEVLK RYD20JEVLK FHYC25JEVLK RYD25JEVLK FHYC30JE...

Страница 2: ......

Страница 3: ...L R Y D20JEVLK 855 628 328 520 179 46 93 149 101 113 603 126 R Y D25 30JEVLK 855 730 328 520 179 46 93 149 101 113 603 126 Dimension Model M N O P Q R S R Y D20JEVLK 164 15 34 23 362 73 75 R Y D25 30...

Страница 4: ...2 Outdoor Unit All dimensions are in mm I J J D M E B G O Dimension Model A B C D E F G H I J K L M N O R Y D40JEVLK R Y D50JETLK 1030 826 400 410 57 72 90 40 746 142 60 26 448 22 28 N N K A L E F H...

Страница 5: ...orted pictures and static Depending on the type and source of the electrical waves static may be heard even when more than 1m away Please take note of the following important points when installing Do...

Страница 6: ...box from the top side of the unit This product is not designed for re packing In case of re packing contact to Daikin Dealer C K U N K E E P B A R For model FH Y C20 25 30 40 50JEVLK Carton Box Top 1...

Страница 7: ...t pressure on the resin parts when opening the unit or when moving it after opening Do not move the unit from packaging while moving until it reaches the installation site Use safe material or protect...

Страница 8: ...ole for the angle nut on the ceiling and fix the hanging rod The installation template is extended according to temperature and humidity Check on dimensions in use The dimensions of the installation t...

Страница 9: ...ompleted connect the flexible drain hose to the drain connector on the indoor unit Drain Test NOTE This Indoor Unit uses a drain pump for condensed water drainage Install the unit horizontally to prev...

Страница 10: ...l be followed Con rm that the unit had been switched off before servicing the unit Use screwdriver to unlock the screw on the grille lock cover Remove the grille lock cover and open the intake grille...

Страница 11: ...l power supply wires and wires from outdoor unit Remove wire cover by removing 2 screws as shown in Figure C Wires will go through the hole as shown in Figure D and E respectively without crossing the...

Страница 12: ...Allow sufficient space for maintenance around the unit Ensure that there is no obstruction of air ow into or out of the unit Remove obstacles which block air intake or discharge The location must be w...

Страница 13: ...Obstacle Obstacle Service Space Obstacle C D Obstacle REFRIGERANT PIPING Maximum Allowable Pipe Length and Elevation If the piping is too long both the capacity and reliability of unit will drop As t...

Страница 14: ...t the flare nuts mounted on the connection parts of both the indoor unit and outdoor unit into the copper pipes The exact length of pipe protruding from the top surface of the swaging block is determi...

Страница 15: ...or 220V 1Ph 60Hz Power supply cable size mm2 Number of conductors 4 0 3 Interconnection cable size mm2 Number of conductors 2 5 4 Recommended time delay fuse A 30 There must be an all pole disconnecti...

Страница 16: ...ge range Indoor 220V 1Ph 60Hz Outdoor 220V 3N 60Hz Power supply cable size mm2 Number of conductors 6 0 3 Interconnection cable size mm2 Number of conductors 2 5 4 Recommended time delay fuse A 35 The...

Страница 17: ...N Indoor Unit Terminal Block Interconnection Cable Outdoor Unit Terminal Block Power Supply Cable Model Indoor FHYC30JEVLK Outdoor RYD30JEVLK Voltage range Indoor 220V 1Ph 60Hz Outdoor 220V 1Ph 60Hz P...

Страница 18: ...uctors 2 5 4 3 Recommended time delay fuse A 35 Model Indoor FHYC40JEVLK Outdoor RYD40JEVLK Voltage range Indoor 220V 1Ph 60Hz Outdoor 220V 1Ph 60Hz Power supply cable size mm2 Number of conductors 6...

Страница 19: ...for connecting wires to the power supply terminal block Connect the wires by matching to the indication on terminal block Refer to the wiring diagram attached on the unit Use the correct screwdriver...

Страница 20: ...the suction valve 3 way and liquid valve 2 way in anti clockwise direction with 4mm key for hexagon sacked screw Charge Operation This operation must be done by using a gas cylinder and a precise wei...

Страница 21: ...FHC30JEVLK FHC40JEVLK Outdoor RD30JEVLK RD40JEVLK Additional charge g m 57 40 Model Indoor FHC50JEVLK Outdoor RD50JETLK Additional charge g m 58 Heat Pump Unit Model Indoor FHYC20JEVLK FHYC25JEVLK Ou...

Страница 22: ...Minimal equipment is required for field charging The minimum equipment required to do a satisfactory job is Set of service gauges 1 Vacuum gauge 4 Hoses 2 Scales 5 Vacuum pump 3 Thermometer 6 The prop...

Страница 23: ...o that it does not touch the air louver Be sure not to push the sealing material in any farther than about 10mm There are many ways of charging liquid in a controlled manner into the suction side Use...

Страница 24: ...Code 1 Room Sensor Open or Short Blink 1 time Blink Fan Blink E1 2 Indoor Coil Sensor Open Blink 2 times Blink Sleep Blink E2 3 Outdoor Coil Sensor Open Blink 3 times Blink Dry Blink E3 4 Compressor...

Страница 25: ...r phase protector under normal operation and fault conditions NOTE 1 indicates additional functions for PP01 phase protector 2 When R phase missing no LED or buzzer will indicate the error but relay 7...

Страница 26: ...power plug is disconnected It is possible that your delay timer has been set incorrectly The air flow is too low 3 The air filter is dirty The air suction and discharge are clogged The regulated temp...

Страница 27: ...o Daikin Dealer Additional refrigerant charge of 0 2kg is needed in order to achieve the stated performance data MODEL INDOOR UNIT FHYC20JEVLK FHYC25JEVLK OUTDOOR UNIT RYD20JEVLK RYD25JEVLK RATED VOLT...