3D027503-1
FHYP35
∼
125BV1
1-RED, 2-WHITE, 3-BLACK
33A
Limit switch (swing flap)
A1P
Printed circuit board
C1R
Capacitor (M1F)
HAP
Light emitting diode (service monitor green)
HBP
Light emitting diode (service monitor green)
M1A
Motor (swing flap)
M1F
Motor (indoor fan)
Q1F
Thermo switch (M1F embedded)
R1T
Thermistor (air)
R2T
Thermistor (coil)
RyA
Magnetic relay (M1A)
RyP
Magnetic relay (M1P)
SS1
Selector switch (emergency)
T1R
Transformer
X1M
Terminal strip
X2M
Terminal strip
?
Signal receiver circuit
.
Signal transmission circuit
=
Phase control circuit
Wired remote control
R1T
Thermistor (air)
SS1
Selector switch (main/sub)
Infrared remote control
Receiver / display unit
A3P
Printed circuit board
A4P
Printed circuit board
BS
Push button (on/off)
H1P
Light emitting diode (service monitor red)
H2P
Light emitting diode (service monitor green)
H3P
Light emitting diode (service monitor red)
H4P
Light emitting diode (service monitor orange)
SS1
Selector switch (main/sub)
SS2
Selector switch (wireless address set)
Connector for optional parts
X15A
Connector (float switch)
X25A
Connector (drain pump)
X30A
Connector (interface adaptor for sky air series)
X33A
Connector (adaptor for wiring)
X35A
Connector (group control adaptor)
X40A
Connector
ON/OFF input from outside
Switch box
To outdoor
unit
Note) 4
Wired remote
control
In case of simultaneous
operation system.
To
outdoor
unit
Notes
1.
D
: Terminal
F
,
H
: Connector
b
: Protective earth (screw)
2.
B
: Field wiring
3. In case using central remote controller, connect it to the
unit in accordance with the attached instruction manual.
4. X24A is connected when the remote controller kit is
being used.
5. Remote controller model varies according to the
combination system, confirm technical materials and
catalogs, etc. before connecting.
6. Symbols show as follows Red:red, Blk:black, Ylw:yellow,
Org:orange, Gry:gray, Prp:purple, Blu:blue
7. Confirm the method of setting the selector switch (SS1,
SS2) by installation manual and engeneering materials,
etc.
Receiver / display unit
Indoor unit
(master)
Indoor unit
(slave)
Remote
controller
Note) 6
Note) 6
Note) 4
•
Ceiling Suspended Unit
•
R-407C
•
FH(Y)-GZ/BZ/FHYP-B
5
Wiring diagrams
10
5
15
•
Split - Sky Air
•
Indoor Units