Operate in the following order.

Press OPERATION MODE SELECTOR but-
ton several times and select the OPERA-
TION MODE of your choice as follows.

„

 

COOLING OPERATION ........................ “

 

 

„

 

HEATING OPERATION ......................... “

 

 

„

 

AUTOMATIC OPERATION .................... “

 

 

• In this operation mode,COOL/HEAT 

changeover is automatically conducted.

„

 

FAN OPERATION  ................................. “

 

 

„

 

DRY OPERATION ................................. “

 

 

• The function of this program is to decrease 

the humidity in your room with the minimum 
temperature decrease.

• Micro computer automatically determines 

TEMPERATURE and FAN SPEED.

• This system dose not go into operation if the 

room temperature is below 16

°

C.

• For cooling only type, “

 

COOLING

 

”, “ FAN ” and 

“ DRY ” operation are able to select.

Press ON/OFF button

OPERATION lamp lights up or goes off and the sys-
tem starts or stops OPERATION.

[EXPLANATION OF HEATING OPERATION]

(1) DEFROST OPERATION

• As the frost on the coil of an outdoor unit 

increase, heating effect decreases and the 
system goes into DEFROST OPERATION.

• The indoor unit fan stops and the remote con-

troller display shows“ 

 ”.

• After 6 to 8 minutes (maximum 10 minutes) of 

DEFROST OPERATION, the system returns 
to HEATING OPERATION.

(2) HOT START

• In order to prevent cold air from blowing out of 

an indoor unit at the start of heating operation, 
the indoor fan is automatically stopped. The 
display of the remote controller shows 
“ 

 ” (DEFROST/HOT START).

(3) OPERATION START

• For ordinary heating, it will take longer for the 

room temperature to reach the set tempera-
ture than with cooling. We therefore recom-
mend starting the unit ahead of time using the 
timer operation.

Regarding outside air temperature and 
heating capacity

• The heating capacity of the air conditioner 

declines as the outside air temperature falls.
In such a case, use the air conditioner in combi-
nation with other heating systems.

• A warm air circulating system is employed, and 

therefore it takes some time until the entire room 
is warmed up after the start of operation.

• An indoor fan runs to discharge a gentle wind 

automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays“ 

 ”. Leave it 

as it stands and wait for a while.

• When the warm air stays under the ceiling and 

your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room). For details,consult your dealer.

For programming TEMPERATURE, FAN SPEED 
and AIR FLOW DIRECTION, follow the procedure 
shown below.

Press TEMPERATURE SETTING button and 
program the setting temperature.

• The setting is impossible for fan operation.

NOTE

• The setting temperature range of the remote con-

troller is 16

°

C to 32

°

C.

Press FAN SPEED CONTROL button.

High or Low fan speed can be selected.
Micro computer may sometimes control the fan 
speed in order to protect the unit.

COOLING, HEATING, AUTOMATIC, FAN, 
AND PROGRAM DRY OPERATION

OPERATION MODE SELEC-
TOR

1

Refer to figure 3 on page

 [1]

ON/OFF

2

ADJUSTMENT

Each time this button is pressed,setting 
temperature rises 1

°

C. 

Each time this button is pressed, set-
ting temperature lowers 1

°

C.

TEMPERATURE SETTING

FAN SPEED CONTROL

01_EN_3P184442-4D.fm  Page 6  Monday, May 11, 2009  1:52 PM

Содержание FFQ25BV1B

Страница 1: ...MODELS Ceiling mounted Multi flow Cassette type FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B SPLIT SYSTEM Air Conditioner OPERATION MANUAL 00_CV1_3P184442 4D fm Page 1 Saturday April 25 2009 1 09 PM...

Страница 2: ...1 1 3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 a b c d e e f g h i k e f l d j C hr H 00_CV2_3P184442 4D fm Page 1 Thursday April 23 2009 5 28 P...

Страница 3: ...y read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual file it away for future referenc...

Страница 4: ...the following control system type Group control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote controllers control system Two remote controller...

Страница 5: ...noxious gas Do not longer use the air conditioner until a qual ified service person confirms that the leakage has been repaired Consult your local dealer regarding what to do in case of refrigerant l...

Страница 6: ...r outlets Impaired air flow may result in insufficient perfor mance or trouble Be sure that children plants or animals are not exposed directly to airflow from the unit as adverse effects may ensue Do...

Страница 7: ...dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this air conditioner and that all electrical work is carried out by qualified per sonnel according to loc...

Страница 8: ...rature 9 DISPLAY FAN SPEED This display shows the set fan speed 10 DISPLAY AIR FLOW FLAP Refer to AIR FLOW DIRECTION ADJUST 11 DISPLAY TIME TO CLEAN AIR FIL TER Refer to HOW TO CLEAN THE AIR FILTER 12...

Страница 9: ...re recom mend starting the unit ahead of time using the timer operation Regarding outside air temperature and heating capacity The heating capacity of the air conditioner declines as the outside air t...

Страница 10: ...the stop time can be simulta neously programmed Press the TIMER MODE START STOP but ton several times and select the mode on the display The display flashes For setting the timer stop For setting the...

Страница 11: ...g cooling or dry operation and set it downwards during heat ing operation Do not let the air blow directly to a person It takes time for the room temperature to reach the set temperature We recommend...

Страница 12: ...tral detergent When the flap is extremely contaminated remove it as below and clean or exchange it For changing the flap please contact your dealer NOTE Do not use gasoline benzene thinner polishing p...

Страница 13: ...he display shows UNDER CENTRALIZED CONTROL and it flashes for few seconds after pressing an operation button This is because the system is under centralized control Flashes on the display indicates th...

Страница 14: ...n COOLING OPERATION or at a stop The noise is heard when the drain pump is in operation A Pishi pishi squeaking sound is heard when the system is in operation or after the stop of operation Expansion...

Страница 15: ...clogged Ask a qualified service person to clean the air fil ters Refer to MAINTENANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outlet of the indoor or the o...

Страница 16: ...0906 HT 3P184442 4D EM09A010 00_CV1_3P184442 4D fm Page 2 Saturday April 25 2009 1 09 PM...

Отзывы: