• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB
• Split Sky Air • Indoor Units
6
5
Dimensional drawing & centre of gravity
5 - 1
Dimensional drawing with standard panel
FCQH71D8
3TW
2
8894-1C
Nr
Name
Descri
p
tion
1
Li
q
uid
p
i
p
e connection
ø
9
.5
2
flare connection
2
G
as
p
i
p
e connection
ø 15.
9
0 flare connection
3
Drain
p
i
p
e connection
VP2
5 (O.D. ø3
2
, I.D. ø
2
5)
4
P
ower su
pp
ly connection
5
Transmission wiring connection
6
Air discharge o
p
ening
7
Air suction grill
8
C
orner decoration co
v
er
9
Drain house
O.D. ø3
2
I.D. ø
2
6
V
iew A
NOTES
1
Location of the name
p
lates:
- Unit body: on the control box co
v
er.
- Decoration
p
anel: on the
p
anel frame at the motor side
under the co
v
er
2
W
hen installing an o
p
tional accessory, refer to the installation
- For the fresh air intake kit ... an ins
p
ection
p
ort is necessary
Drain side
P
i
p
ing side
See note 3
860 -
9
10 (
C
eiling o
p
ening)
710 (Sus
p
ension
p
osition)
See note 4
860 -
9
10
(
C
ei
ling o
p
eni
ng
)
780 (Sus
p
ens
ion
p
os
iti
on)
See note 4
See note 4
9
50
9
50
4
2
0
4
2
0
55
55
840
340
2
80
330
Hanging bolt
4 x M8-M10
50
40
2
46
10
850
Adj
us
tabl
e (0-
675)
2
56
16
5
175
1
2
5
35
35
55
840
130
1500 or
more
(Ins
taal
ati
on
s
p
ac
e)
2
00 mm
or more
1500 mm
or more (*)
1500 mm
or more (*)
1500 mm
or more (*)
2
00 mm
or more
V
entilator
Other unit
External surface
light
1500 mm or more
2
000 mm or more
4000 mm or more
1
2
3
In case of using a Infrared remote control, this
p
osition will be a signal recei
v
er.
Refer to the drawing of the infrared remote control for more detail
4
Make sure the s
p
acing between the ceiling and the cassette is no more than 35 mm. Max ceiling o
p
ening:
9
10 mm.
5
W
hen the conditions exceed 30°
C
and RH 80% in the ceiling or fresh air is inducted, into the ceiling, an additional
insulation is re
q
uired (
p
olyethylene foam, thickness 10 mm or more.)
(*) In case a discharge o
p
ening is closed with the ‘sealing member’ o
p
tion, the distance of 1500 mm can be reduced to 500 mm on the closed side.
300 or less
1500 mm
or more (*)
55
FCQH100-140D8
3TW
2
8914-1C
P
i
p
ing side
Drain side
see note 3
see note 4
300 or less
(
C
eiling o
p
ening)
(Sus
p
ension
p
osition)
(Sus
p
ens
ion
p
os
itio
n)
(
C
ei
ling
o
p
eni
ng)
P
lease res
p
ect the distances as shown on figure below
Other unit
V
entilator
External
surface
light
1500 or more
2
000 or more
4000 or more
1500 mm
or more (*)
1500 mm
or more (*)
1500 mm
or more (*)
1500 mm
or more (*)
2
00 mm
or more
2
00 mm
or more
(*) In case a discharge o
p
ening is closed with
the “sealing member” o
p
tion, the distance of
1500 mm can be reduced to 500 mm on the
closed side.
see note 4
see note 4
Hanging bolt
adj
us
tabl
e
15
00 or
mor
e
(Sus
p
ens
ion
p
os
iti
on)
V
iew A
V
iew B
Item
Name
Remark
1
Li
q
uid
p
i
p
e connection
ø
9
.5
2
(Flare connection)
2
G
as
p
i
p
e connection
ø15.
9
0 (Flare connection)
3
Drain
p
i
p
e connection
VP2
5 (ODø3
2
, IDø
2
5)
4
P
ower su
pp
ly entry hole
5
Transmission wiring entry hole
6
Air discharge o
p
ening
7
Air suction grille
8
C
orner decoration co
v
er
9
Drain hose
ODø3
2
, IDø
2
5
10
Knock out hole
NOTE
1
Location of the name
p
lates - Unit body: on the control box - Decoration
p
anel: on the
p
anel frame at the motor side under the corner co
v
er
2
W
hen installing an o
p
tional accessory, refer to the installation drawings
For the fresh air intake kit an ins
p
ection
p
ort is necessary
3
In case of using a wireles remote control, this
p
osition will be a signal recei
v
er. Refer to the drawing of the wireless remote control for more detail.
4
Make sure the s
p
acing between the ceiling and the cassette is no more than 35mm. Max cailing o
p
ening:
9
10mm.
5
W
hen the conditions exceed 30°
C
and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additionalinsulation is re
q
uired (
p
olyethylene foam,
thickness 10mm or more).