• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB

• Split Sky Air • Indoor Units

6

5

Dimensional drawing & centre of gravity

5 - 1

Dimensional drawing with standard panel

FCQH71D8

3TW

2

8894-1C

Nr

Name

Descri

p

tion

1

Li

q

uid 

p

i

p

e connection

ø 

9

.5

2

 flare connection

2

G

as 

p

i

p

e connection

ø 15.

9

0 flare connection

3

Drain 

p

i

p

e connection

VP2

5 (O.D. ø3

2

, I.D. ø

2

5)

4

P

ower su

pp

ly connection

5

Transmission wiring connection

6

Air discharge o

p

ening

7

Air suction grill

8

C

orner decoration co

v

er

9

Drain house

O.D. ø3

2

   I.D. ø

2

6

V

iew A

NOTES

1

Location of the name

p

lates:

- Unit body: on the control box co

v

er.

- Decoration 

p

anel: on the 

p

anel frame at the motor side

                              under the co

v

er

2

W

hen installing an o

p

tional accessory, refer to the installation

- For the fresh air intake kit  ... an ins

p

ection 

p

ort is necessary

Drain side

P

i

p

ing side

See note 3

860 - 

9

10 (

C

eiling o

p

ening)

710 (Sus

p

ension 

p

osition)

See note 4

860 - 

9

10

 (

C

ei

ling o

p

eni

ng

)

780 (Sus

p

ens

ion 

p

os

iti

on)

See note 4

See note 4

9

50

9

50

4

2

0

4

2

0

55

55

840

340

2

80

330

Hanging bolt

4 x M8-M10

50

40

2

46

10

850

Adj

us

tabl

e (0-

675)

2

56

16

5

175

1

2

5

35

35

55

840

130

1500 or 

more

(Ins

taal

ati

on

 s

p

ac

e)

2

00 mm

or more

1500 mm

or more (*)

1500 mm

or more (*)

1500 mm

or more (*)

2

00 mm

or more

V

entilator

Other unit

External surface

light

1500 mm or more

2

000 mm or more

4000 mm or more

1

2

3

In case of using a Infrared remote control, this 

p

osition will be a signal recei

v

er.

Refer to the drawing of the infrared remote control for more detail

4

Make sure  the s

p

acing between the ceiling and the cassette is no more than 35 mm. Max ceiling o

p

ening: 

9

10 mm.

5

W

hen the conditions exceed 30°

C

 and RH 80% in the ceiling or fresh air is inducted, into the ceiling, an additional 

insulation is re

q

uired (

p

olyethylene foam, thickness 10 mm or more.) 

(*) In case a discharge o

p

ening is closed with the ‘sealing member’ o

p

tion, the distance of 1500 mm can be reduced to 500 mm on the closed side.

300 or less

1500 mm

or more (*)

55

FCQH100-140D8

3TW

2

8914-1C

P

i

p

ing side

Drain side

see note 3

see note 4

300 or less

(

C

eiling o

p

ening)

(Sus

p

ension 

p

osition)

(Sus

p

ens

ion 

p

os

itio

n)

(

C

ei

ling

 o

p

eni

ng)

P

lease res

p

ect the distances as shown on figure below

Other unit

V

entilator

External 

surface 

light

1500 or more

2

000 or more

4000 or more

1500 mm 
or more (*)

1500 mm 
or more (*)

1500 mm 
or more (*)

1500 mm 
or more (*)

2

00 mm 

or more

2

00 mm 

or more

(*) In case a discharge o

p

ening is closed with 

the “sealing member” o

p

tion, the distance of 

1500 mm can be reduced to 500 mm on the 
closed side. 

see note 4

see note 4

Hanging bolt

adj

us

tabl

e

15

00 or

 mor

(Sus

p

ens

ion 

p

os

iti

on)

V

iew A

V

iew B

Item

Name

Remark

1

Li

q

uid 

p

i

p

e connection

ø

9

.5

2

 (Flare connection)

2

G

as 

p

i

p

e connection

ø15.

9

0 (Flare connection)

3

Drain 

p

i

p

e connection

VP2

5 (ODø3

2

, IDø

2

5)

4

P

ower su

pp

ly entry hole

5

Transmission wiring entry hole

6

Air discharge o

p

ening

7

Air suction grille

8

C

orner decoration co

v

er

9

Drain hose

ODø3

2

, IDø

2

5

10

Knock out hole

NOTE

1

Location of the name

p

lates - Unit body: on the control box - Decoration 

p

anel: on the 

p

anel frame at the motor side under the corner co

v

er

2

W

hen installing an o

p

tional accessory, refer to the installation drawings

For the fresh air intake kit an ins

p

ection 

p

ort is necessary

3

In case of using a wireles remote control, this 

p

osition will be a signal recei

v

er. Refer to the drawing of the wireless remote control for more detail.

4

Make sure the s

p

acing between the ceiling and the cassette is no more than 35mm. Max cailing o

p

ening: 

9

10mm.

5

W

hen the conditions exceed 30°

C

 and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additionalinsulation is re

q

uired (

p

olyethylene foam, 

thickness 10mm or more).

Содержание FCQH100D8VEB

Страница 1: ...Cooling Only Heat Pump FCQH D8VEB air conditioning systems technical data...

Страница 2: ...Cooling Only Heat Pump FCQH D8VEB air conditioning systems technical data...

Страница 3: ...afety device settings 4 4 Options 5 5 Dimensional drawing centre of gravity 6 Dimensional drawing with standard panel 6 Dimensional drawing with auto cleaning panel 7 Dimensional drawing with accessoi...

Страница 4: ...el in full white RAL9010 including white louvers auto cleaning panel 23 different air flow patterns possible Drain up pump with 850mm lift fitted as standard For auto cleaning panel Daikin introduces...

Страница 5: ...21 9 34 2 34 2 34 2 Low m min 12 1 17 6 21 2 23 8 Heating High m min 21 9 34 2 34 2 34 2 Low m min 12 1 17 6 21 3 23 9 Fan Motor Model QTS48C15M Number of steps 3 Output high W 120 Cooling Sound Power...

Страница 6: ...f dirt on white insulations is more visible and that it is consequently not advised to install the BYCQ140W1W decoration panel in environments exposed to concentrations of dirt 2 2 Electrical Specific...

Страница 7: ...LU LQWDNH NLW IUHVK DLU KDPEHU W SH 4 6HDOLQJ PHPEHU RI DLU GLVFKDUJH RXWOHW 4 21752 6 67 0 WHP 0RGHO 4 4 4 4 4 4 4 4 4 4 4 5HPRWH FRQWURO LUHOHVV 3 5 2 5 LUHG 5 5 LULQJ DGDSWRU IRU HOHFWULFDO DSSHQGL...

Страница 8: ...d polyethylene foam thickness 10 mm or more In case a discharge opening is closed with the sealing member option the distance of 1500 mm can be reduced to 500 mm on the closed side 300 or less 1500 mm...

Страница 9: ...more 4 1500mm or more 4 1500mm or more 4 4 In case a discharge opening is closed with the sealing member option the distance of 1500mm can be reduced to 500 mm on the closed side FCQH100 140D8VEB 3TW...

Страница 10: ...atic pressure of chamber Pa Inlet 306 In case a discharge opening is closed with the sealing member option the distance of 1500 mm can be reduced to 500 mm on the closed side FCQH100 125 140D8 3D05703...

Страница 11: ...dimensions Pipe connection side Drain connection side Receiver installation procedure Receiver Decoration panel Remote controller holder installation procedure installation to wall surface Receiver de...

Страница 12: ...Indoor Units 10 Indoor Units Cooling Only Heat Pump FCQH D8VEB 5 Dimensional drawing centre of gravity 5 5 Centre of gravity FCQH71 140D8 4TW28839 2 Models A B C D FCQH71 246 90 411 411 FCQH100 140 2...

Страница 13: ...door Units Cooling Only Heat Pump FCQH D8VEB 6 Piping diagram FCQH71 140D8 3TW28925 1A Cooling Heating Liquid pipe connection port Gas pipe connection port Heat exchanger Fan Model Gas Liquid FCQH71 1...

Страница 14: ...etic relay M1P H1P Light emitting diode On red M1F Motor Indoor fan H2P Light emitting diode Timer green M1P Motor Drain pump H3P Light emitting diode Filter sign red M1S Motor Swing ap H4P Light emit...

Страница 15: ...weighted sound power level A scale according to IEC 5 Reference acoustic intensity 0dB 20 Pa Sound power level dB Octave band center frequency Hz Mic position FCQH125D8 3TW31777 3 NOTES 1 High tap Low...

Страница 16: ...scale according to IEC 3 Reference acoustic intensity 0dB 10E 6 W m2 4 Measured according to ISO 3744 Sound power level dB Octave band center frequency Hz FCQH100 140D8 3TW31767 1 NOTES 1 High tap 2...

Страница 17: ...13 Cooling air temperature distribution All round air discharge air flow direction horizontal Cooling air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m...

Страница 18: ...Cooling air temperature distribution All round air discharge air flow direction horizontal Cooling air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m...

Страница 19: ...Cooling air temperature distribution All round air discharge air flow direction horizontal Cooling air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m...

Страница 20: ...Cooling air temperature distribution All round air discharge air flow direction horizontal Cooling air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m...

Страница 21: ...air temperature distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 4m...

Страница 22: ...temperature distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m...

Страница 23: ...temperature distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m...

Страница 24: ...temperature distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m...

Страница 25: ...N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publication All content is copyrighted by...

Отзывы: