11 Before operation

Installation and operation manual

13

FCAG35~140BVEB
Split system air conditioners
4P535626-1C – 2019.09

11

Before operation

WARNING

This unit contains electrical and hot parts.

WARNING

Before operating the unit, be sure the installation has been
carried out correctly by an installer.

CAUTION

It is not good for your health to expose your body to the air
flow for a long time.

CAUTION

To  avoid  oxygen  deficiency,  ventilate  the  room  sufficiently
if equipment with burner is used together with the system.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

NOTICE

Be  sure  to  turn  on  the  power  6  hours  before  operation  in
order  to  have  power  running  to  the  crankcase  heater  and
to protect the compressor.

This  operation  manual  is  for  the  following  systems  with  standard
control.  Before  initiating  operation,  contact  your  dealer  for  the
operation  that  corresponds  to  your  system  type  and  mark.  If  your
installation has a customised control system, ask your dealer for the
operation that corresponds to your system.

Operation modes:

▪ Heating and cooling (air to air).

▪ Fan only operation (air to air).

12

Operation

12.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

In combination with R410A outdoor units

Outdoor units

Cooling

Heating

RR71~125

–15~46°C DB

12~28°C WB

RQ71~125

–5~46°C DB

–10~15°C WB

12~28°C WB

10~27°C DB

RXS35~60

–10~46°C DB

–15~18°C WB

14~28°C WB

10~30°C DB

3MXS40~68

4MXS68~80

5MXS90

–10~46°C DB

–15~18°C WB

14~28°C WB

10~30°C DB

RZQG71~140

–15~50°C DB

–20~15.5°C WB

12~28°C WB

10~27°C DB

In combination with R410A outdoor units

Outdoor units

Cooling

Heating

RZQSG71~140

–15~46°C DB

–15~15.5°C WB

14~28°C WB

10~27°C DB

RZQ200~250

–5~46°C DB

–15~15°C WB

14~28°C WB

10~27°C DB

AZQS71

–15~46°C DB

–15~15.5°C WB

14~28°C WB

10~27°C DB

AZQS100~140

–5~46°C DB

–15~15.5°C WB

14~28°C WB

10~27°C DB

Indoor humidity

≤80%

(a)

Indoor humidity

In combination with R32 outdoor units

Outdoor units

Cooling

Heating

RXM35~60

–10~46°C DB

–15~24°C DB

–15~18°C WB

14~28°C DB

10~30°C DB

3MXM40~68

4MXM68~80

5MXM90

–10~46°C DB

–15~24°C DB

–15~18°C WB

18~37°C DB

14~28°C WB

10~30°C DB

RZAG35~60

–20~52°C DB

–20~24°C DB

–21~18°C WB

17~38°C DB

12~28°C WB

10~27°C DB

RZAG71~140

–20~52°C DB

–20~24°C DB

–20~18°C WB

17~38°C DB

12~28°C WB

10~27°C DB

RZASG71~140

–15~46°C DB

–15~21°C DB

–15~15.5°C WB

20~38°C DB

14~28°C WB

10~27°C DB

AZAS71~140

–5~46°C DB

–15~21°C DB

–15~15.5°C WB

20~38°C DB

14~28°C WB

10~27°C DB

Indoor humidity

≤80%

(a)

Symbol

Explanation

Outdoor temperature

Indoor temperature

(a)

To avoid condensation and water dripping out of the unit. If
the temperature or the humidity is beyond these conditions,
safety devices may be put in action and the air conditioner
may not operate.

Содержание FCAG35BVEB

Страница 1: ...tion and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FCAG35BVEB FCAG50BVEB FCAG60BVEB FCAG71BVEB FCAG100BVEB FCAG125BVEB FCAG...

Страница 2: ...ojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmis t e standardi te ga v i teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurody...

Страница 3: ...tion airflow 14 12 5 1 To start the active circulation airflow 14 13 Maintenance and service 15 13 1 Precautions for maintenance and service 15 13 2 Cleaning the air filter suction grille air outlet a...

Страница 4: ...from easy access This unit both indoor and outdoor is suitable for installation in a commercial and light industrial environment Spacing Mind the following requirements mm 1500 2000 4000 1500 A B C b...

Страница 5: ...Nut field supply a2 Double nut field supply b Washer accessories c Hanger bracket attached to the unit Paper pattern for installation upper part of the packing Use the paper pattern to determine the...

Страница 6: ...mp accessory b Drain hose accessory c Rising drain piping vinyl pipe of 25 mm nominal diameter and 32 mm outer diameter field supply d Hanging bars field supply Condensation Take measures against cond...

Страница 7: ...ted of materials that are inherently resistant to corrosion or are suitably protected against corrosion WARNING FLAMMABLE MATERIAL The R32 refrigerant if applicable in this unit is mildly flammable Re...

Страница 8: ...h the numbers on the outdoor unit and connect the earth wire and fix the cable with a cable tie 4 Divide the small sealing accessory and wrap it around the cables to prevent water from entering the un...

Страница 9: ...e installation manual of the user interface If you want an interval of air contamination Then 1 M C1 C2 2500 h light 10 20 0 01 1250 h heavy 02 No notification 3 02 Individual setting in a simultaneou...

Страница 10: ...terface When using any other user interface see the installation manual or service manual of the user interface NOTICE Do not interrupt the test run INFORMATION Backlight To perform an ON OFF action o...

Страница 11: ...ical wires Error code Possible cause U4 or UF The inter unit branch wiring is not correct UA The outdoor and indoor unit are incompatible 7 Disposal NOTICE Do NOT try to dismantle the system yourself...

Страница 12: ...ixed plate T R Transformer TC TRC Transmitter V R V Varistor V R Diode bridge WRC Wireless remote controller X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing s...

Страница 13: ...ty ranges for safe and effective operation In combination with R410A outdoor units Outdoor units Cooling Heating RR71 125 15 46 C DB 12 28 C WB RQ71 125 5 46 C DB 10 15 C WB 12 28 C WB 10 27 C DB RXS3...

Страница 14: ...the dry program The function of this program is to decrease the humidity in your room with minimal temperature decrease minimal room cooling The micro computer automatically determines temperature an...

Страница 15: ...or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire CAUTION After a long use check the unit stand and fitting for damage If damaged the uni...

Страница 16: ...air filter 1 2 3 4 Clean the suction grille Wash with a soft bristle brush and water or neutral detergent If the suction grille is very dirty use a typical kitchen cleaner leave it on for 10 min then...

Страница 17: ...em is odourless WARNING R410A is a non combustible refrigerant and R32 is a mildly flammable refrigerant they normally don t leak If the refrigerant leaks in the room and comes into contact with fire...

Страница 18: ......

Страница 19: ......

Страница 20: ...4P535626 1C 2019 09 Copyright 2018 Daikin...

Отзывы: