Installation is possible when ceiling opening dimensions is as follows.
• When installing the unit within the frame for fixing false ceiling.
I
840
I
910
(Dimension inside frame)
Fig. 6
NOTE
-:ni
(unit: mm)
Frame
False
ceiling
860
(Opening dimension inside
the flame for ceiling)
(Ceiling opening d1mens1on) (Ceiling-panel
overlapping dimension)
Fig. 7
(unit : mm)
• Installation is possible with a ceiling dimension of 91 O mm (marked with *). However, to achieve a ceiling
panel overlapping dimension of 20 mm, the spacing between the ceiling and the unit should be 35 mm or
less. If the spacing between ceiling and the unit is over 35 mm, attach ceiling material to • part or
recover the ceiling.
Ceiling material
�35
Fig. 8
�35
(unit: mm)
(2) Make the ceiling opening needed for installation where applicable.
(For existing ceilings)
• Refer to the paper pattern for installation (5) for ceiling opening dimensions.
• Create the ceiling opening required for installation. From the side of the opening to the casing outlet,
implement the refrigerant and drain piping and wiring for remote controller (unnecessary for wireless
type) and indoor-outdoor unit casing outlet. Refer to
"6. REFRIGERANT PIPING WORK", "7. DRAIN
PIPING WORK"
and
"8. ELECTRIC WIRING WORK".
• After making an opening in the ceiling, it may be necessary to reinforce ceiling beams to keep the ceiling
level and to prevent it from vibrating. Consult the builder for details.
(3) Install the suspension bolts.
• Use MB or M10 bolts for hanging the indoor unit.
Use a hole-in anchor for existing ceilings, and
a sunken insert, sunken anchor or other field
supplied parts for new ceilings to reinforce
the ceiling to bear the weight of the unit.
Adjust clearance (50 - 100 mm) from the
ceiling before proceeding further.
NOTE
-:ni
• All the above parts are field supplied.
8
<installation example>
Ceiling slab
Anchor
Long nut or turn-buckle
Suspension bolt
zz==
---
+--
--
e1:
2
\C�il�surface
Fig. 9
(unit: mm)
I
Содержание FCA71AV16
Страница 34: ...33 RZCA71AV16...
Страница 35: ...34 RZCA71AV16...
Страница 36: ...35...
Страница 37: ...36...
Страница 38: ...37...
Страница 39: ...38 RZCA71AV16...
Страница 40: ...39 RZCA71AV16...
Страница 41: ...40...
Страница 42: ...41...
Страница 43: ...42 RZCA71AV16 RZCA71AV16 20 g per meter For Piping Length Exceeding 10 m RZCA71AV16...
Страница 44: ...43 45...
Страница 45: ...44 RZCA71AV16 RZCA71AV16...
Страница 46: ...45 RZCA71AV16 RZCA71AV16 Power Supply 50 Hz 230 V...
Страница 47: ...46...
Страница 50: ...49...
Страница 51: ...50 RZCA71AV16...
Страница 54: ...53 INDOOR FCA71AV16 OUTDOOR RZCA71AV16...