I
DAIKIN
SPLIT SYSTEM AIR CONDITIONER
INSTALLATION MANUAL <FOR INDOOR UNIT>
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
NEW REFRIGERANT (R32) SERI ES
FCA
1
2
5
AV
1
6, FCA
1
40AV
1
6
INSTALLATION MANUAL OF INDOOR
1 ·31
INSTALLATION MANUAL OF OUTDOOR
32.52
CONTENTS
1.
SAFETY PRECAUTIONS .................................................................................................................. 1
2.
BEFORE INSTALLATION................................................................................................................... 3
3.
SELECTING INSTALLATION SITE.................................................................................................... 5
4.
PREPARATION BEFORE INSTALLATION........................................................................................
7
5.
INDOOR UNIT INSTALLATION.......................................................................................................... 9
6.
REFRIGERANT PIPING WORK ......................................................................................................... 11
7.
DRAIN PIPING WORK ....................................................................................................................... 13
8.
ELECTRIC WIRING WORK............................................................................................................... 17
9.
WIRING EXAMPLE ............................................................................................................................. 20
10. INSTALLATION OF THE DECORATION PANEL. .............................................................................. 22
11. FIELD SETTING .................................................................................................................................. 23
12. TEST OPERATION ............................................................................................................................. 26
13. UNPACKING
&
PACKING OF THE INDOOR UNIT ............................................................................. 30
1. SAFETY PRECAUTIONS
Read the precautions in this manual
carefully before operating the unit.
This appliance is filled with R32.
Please read these "SAFETY PRECAUTIONS" carefully before installing air conditioning equipment and be sure to install it
correctly. After completing the installation, make sure that the unit operates properly during the start-up operation.
After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the
air conditioner and take care of it with the aid of the operation manual. Ask the customer to store the installation manual along
with the operation manual for future reference.
This air conditioner comes under the term "appliances not accessible to the general public".
Please instruct the customer on how to operate the unit and keep it maintained.
Also, inform customers that they should store this installation manual along with the operation manual for future reference.
Meaning of WARNING and CAUTION notices.
&
WARNING ........ Failure to follow these instructions properly may result in personal injury or loss of life.
&
C AUTION ........ Failure to observe these instructions properly may result in property damage or personal injury,
which may be serious depending on the circumstances.
-&
WARNING-------------------------
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Carry out the specified installation work after taking into account strong winds, typhoons or earthquakes.
Failure to do so during installation work may result in the unit falling and causing accidents.
• Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qualified
personnel according to local laws and regulations and this installation manual.
An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the
control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or overheating terminals.
1
Содержание FCA125AV16
Страница 68: ...MEMO 3P727715 5 B...