background image

Split - Sky Air

04/2007

Pri

n

ted in

 Belgiu

b

y Goe

kin

t Graphic

s

Copyright 

©

 Da

ik

in

EEDEN0 7

Naamloze Vennootschap

Zandvoordestraat 300

B-8400 Ostend, Belgium

www.daikin.eu

BTW: BE 0412 120 336

RPR Oostende

ISO14001 assures an effective environmental 
management system in order to help protect 
human health and the environment from 
potential impact of our activities, products and 
services and to assist in maintaining and 
improving the quality of the environment.

Daikin Europe N.V. is approved by LRQA for its 
Quality Management System in accordance 
with the ISO9001 standard. ISO9001 pertains 
to quality assurance regarding design, 
development, manufacturing as well as to 
services related to the product.

Daikin units comply with the European 
regulations that guarantee the safety of the 
product.

Daikin Europe N.V. participates in the Eurovent 
Certification Programme for Air Conditioners 
(AC), Liquid Chilling Packages (LCP) and Fan Coil 
units (FC); the certified data of certified models 
are listed in the Eurovent Directory.

Daikin’s unique position as a man-
ufacturer of air conditioning equip-
ment, compressors and refrige-
rants has led to its close involve-
ment in environmental issues. For
several years Daikin has had the in-
tention to become a leader in the
provision of products that have
limited impact on the environ-
ment. This challenge demands the
eco design and development of a
wide range of products and an en-
ergy management system, result-
ing in energy conservation and a
reduction of waste.

“The present publication is drawn up by way of information only and
does not constitute an offer binding upon Daikin Europe N.V.. Daikin
Europe N.V. has compiled the content of this publication to the best
of its knowledge. No express or implied warranty is given for the
completeness, accuracy, reliability or fitness for particular purpose of
its content and the products and services presented therein. Specifi-
cations are subject to change without prior notice. Daikin Europe N.V.
explicitly rejects any liability for any direct or indirect damage, In the
broadest sense, arising from or related to the use and/or interpreta-
tion of this publication. All content is copyrighted by Daikin Europe
N.V..”

Содержание FBQ100B8V3B

Страница 1: ...technical data Split Sky Air air conditioning systems FBQ B8V1 B8V3B...

Страница 2: ...Eurovent Directory Daikin s unique position as a man ufacturer of air conditioning equip ment compressors and refrige rants has led to its close involve ment in environmental issues For several years...

Страница 3: ...technical data Split Sky Air air conditioning systems FBQ B8V1 B8V3B...

Страница 4: ...rical Specifications 7 3 Safety device settings 8 4 Options 9 5 Control systems 10 6 Dimensional drawing centre of gravity 11 Dimensional drawing 11 Centre of gravity 14 7 Piping diagram 15 8 Wiring d...

Страница 5: ...exible installation Blends unobtrusively with any interior d cor only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered enabling efficient t...

Страница 6: ...of Stages 14 14 14 14 14 14 14 Empty Tubeplate Hole 4 14 Tube type Hi XA 7 Hi XA 7 Hi XA 7 Hi XSS 7 Hi XSS 7 Hi XSS 7 Hi XSS 7 Fin Type Rhombus Treatment Hydrophilic Hydrophilic Hydrophilic Hydrophili...

Страница 7: ...Washer for hanger bracket Quantity 8 8 8 8 Item Insulation for piping Screws for duct flanges Quantity 12 12 12 12 Item Paper pattern fixing screws Quantity 6 6 6 6 Item Installation and operation man...

Страница 8: ...ts R 410A FBQ B8V1_FBQ B8V3B 3 Safety device settings Model Safety devices 35 45 50 60 71 100 125 140 FBQ B Fuse 5A 250V 5A 250V 5A 250V Fan motor thermal fuse C 152 2 152 2 152 2 152 2 152 2 152 2 15...

Страница 9: ...creening door KBBJ25K56 KBBJ25K80 KBBJ25K160 Air discharge adapter for round duct KDAJ25K56 KDAJ25K71 KDAJ25K140 Nr Item Type FBQ35 50 FBQ60 71 FBQ100 125 140 1 Remote control Wired type BRC1D52 2 Cen...

Страница 10: ...5 Split Sky Air Indoor Units 10 Indoor Units R 410A FBQ B8V1_FBQ B8V3B 5 Control systems 3TW23651 2 6 5 x 9 Round end slit Cover open Cover closed 5 x 7 Round end slit HoleJ5 5 x 10 Round end slit BRC...

Страница 11: ...ut hole 300mmormore Service space view C Fresh air intake position On circumference 595 Air suction panel center Model A B FBQ35 6 35 9 52 FBQ50 6 35 12 70 3TW22244 1D FBQ60 71B view A 1050 Suspension...

Страница 12: ...pace view C Fresh air intake position On circumference 595 Air suction panel center 3TW22254 1D 630 Suspension position Model A B FBQ100 9 52 15 90 FBQ125 140 9 52 15 90 3TW22224 2C FBQ35 50B With can...

Страница 13: ...35 12 70 FBQ71 9 52 15 90 630 Suspension position With flange 465 mm or more Installation space 1060 Ceiling opening 595 Air suction panel center Ceiling opening FBQ100 125 140B With canvas view A 14...

Страница 14: ...r Indoor Units 14 Indoor Units R 410A FBQ B8V1_FBQ B8V3B 6 Dimensional drawing centre of gravity 6 2 Centre of gravity Model A B FBQ35 50 700 300 FBQ60 1000 460 FBQ71 1000 460 FBQ100 125 140 1400 640...

Страница 15: ...Screw connection N Flange connection Z Pinched pipe P Spinned pipe Heat exchanger Refrigerant flow Cooling Heating Liquid pipe connection port 3TW20435 1L FBQ B Gas pipe connection port Filter Refrige...

Страница 16: ...y ORG Orange BS14 Filter sign reset button H1P Light emitting diode service monitor red LCD Liquid crystal display LCD SS1 Selector switch main sub 2TW26026 1A FBQ71B S1L Float switch A1P Printed circ...

Страница 17: ...on BS12 Inspection test operation button Adapter for wiring RyC RyF Magnetic relay Connector for optional parts X60A X61A Connector interface adapter for sky air series X33A Connector adapter for wiri...

Страница 18: ...re level A scale according to IEC 4 Reference acoustic pressure 0dB 20Pa Legend High speed Low speed Unit Location of microphone Microphone Suction Discharge Sound pressure level dB FBQ100B 3TW22107 1...

Страница 19: ...ion panel Long life filter Air flow m 3 min Internal static pressure A Upper limit of external static pressure high ESP B Lower limit of external static pressure high ESP low A B DU220 413A FBQ60 71B...

Страница 20: ...icates the characteristics of the fan when a suction panel optional accessory and a canvas for the suction panel optional accessory are incorporated into the main unit with a long life filter A Upper...

Страница 21: ...anel Direct installation of inlet panel Ceiling return Wide variety of installation methods Number Description 1 Main body 2 Air outlet duct Field supply 3 Inlet panel Optional accessory 4 Air suction...

Страница 22: ...Units R 410A FBQ B8V1_FBQ B8V3B 11 Installation 11 1 Installation method 3TW22043 4A Drain pump up height Easy access to the switch box Easy modification from rear to bottom suction From the outside o...

Страница 23: ...tion 11 2 Filter installation method Number Description 1 Indoor unit 2 Pipe connections 3 Suspension bolt pitch 4x 4 Suspension bolt pitch distance Unit A B FBQ35 50 700 750 FBQ60 1000 1050 FBQ71 100...

Страница 24: ...l optional 4 Air filter 5 Air inlet duct 6 Duct service opening NOTES 1 When installing the unit with rear suction a service opening is necessary for the maintenance of the air filters 2 When installi...

Страница 25: ...Indoor Units R 410A FBQ B8V1_FBQ B8V3B 1 11 Split Sky Air Indoor Units 25 11 Installation 11 3 Switch box connection 3TW22043 5B FBQ B...