8 Troubleshooting
User reference guide
8
FBA35~1FBA35~71A2VEB9
Split system air conditioners
4P543324-2 – 2018.08
7.6
Maintenance after a long stop
period
E.g., at the beginning of the season.
▪ Check and remove everything that might be blocking inlet and
outlet vents of indoor units and outdoor units.
▪ Check if the earth is connected properly.
▪ Check if there is somewhere a broken wire. Contact your dealer in
case of problems.
▪ Clean air filters and casings of indoor units. Contact your installer
or maintenance person to clean air filters and casings of the
indoor unit. Maintenance tips and procedures for cleaning are
provided in the installation/operation manuals of dedicated indoor
units. Make sure to install cleaned air filters back in the same
position.
▪ Turn on the power at least 6 hours before operating the unit in
order to ensure smoother operation. As soon as the power is
turned on, the user interface display appears.
8
Troubleshooting
If one of the following malfunctions occur, take the measures shown
below and contact your dealer.
WARNING
Stop operation and shut off the power if anything
unusual occurs (burning smells etc.).
Leaving the unit running under such circumstances may
cause breakage, electric shock or fire. Contact your dealer.
The system MUST be repaired by a qualified service person.
Malfunction
Measure
If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.
Turn OFF the main power
switch.
If water leaks from the unit.
Stop the operation.
The operation switch does NOT work
well.
Turn OFF the power
supply.
If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.
Notify your installer and
report the malfunction
code.
If the system does NOT properly operate except for the above
mentioned cases and none of the above mentioned malfunctions is
evident, investigate the system according to the following
procedures.
Malfunction
Measure
If the system does not
operate at all.
▪ Check if there is no power failure. Wait
until power is restored. If a power failure
occurs during operation, the system
automatically restarts immediately after
power is restored.
▪ Check if no fuse has blown or breaker is
activated. Change the fuse or reset the
breaker if necessary.
The system stops
immediately after
starting operation.
▪ Check if air inlet or outlet of outdoor or
indoor unit is not blocked by obstacles.
Remove any obstacles and make sure
the air can flow freely.
▪ Check if the air filter is clogged. Contact
your dealer to clean the air filter.
Malfunction
Measure
The system operates
but cooling or heating
is insufficient.
▪ Check if air inlet or outlet of outdoor or
indoor unit is not blocked by obstacles.
Remove any obstacles and make sure
the air can flow freely.
▪ Check if the air filter is clogged. Contact
your dealer to clean the air filter (refer to
"Maintenance" in the indoor unit manual).
▪ Check the temperature setting. Refer to
the manual of the user interface.
▪ Check if the fan speed setting is set to
low speed. Refer to the manual of the
user interface.
▪ Check if the air flow angle is proper.
Refer to the manual of the user interface.
▪ Check for open doors or windows. Close
doors and windows to prevent wind from
coming in.
▪ Check if direct sunlight enters the room.
Use curtains or blinds.
▪ Check if there are too many occupants in
the room during cooling operation. Check
if the heat source of the room is
excessive.
▪ If the heat source of the room is
excessive (when cooling). Cooling effect
decreases if heat gain of the room is too
large.
Operation stops
suddenly. (Operation
lamp blinks.)
▪ Check if the air filter is clogged. Contact
your dealer to clean the air filter (refer to
"Maintenance" in the indoor unit manual).
▪ Check if air inlet or outlet of outdoor or
indoor unit is not blocked by obstacles.
Remove any obstacles, turn the breaker
OFF and back ON. If the lamp still blinks,
contact your dealer.
▪ Check if all indoor units connected to
outdoor unit in the multi-system are
operating in the same mode.
An abnormal function
happens during
operation.
▪ The air conditioner may malfunction
because of lightning or radio waves. Turn
the breaker OFF and back ON.
If after checking all above items, it is impossible to fix the problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).
8.1
Symptoms that are NOT system
malfunctions
The following symptoms are NOT system malfunctions:
8.1.1
Symptom: The system does not operate
▪ The air conditioner does not start immediately after the ON/OFF
button on the user interface is pressed. If the operation lamp
lights, the air conditioner is in normal condition. It does not restart
immediately because one of its safety devices actuates to prevent
the air conditioner from being overloaded. The air conditioner will
turn on again automatically after 3 minutes.
▪ The air conditioner does not start immediately after the power
supply is turned on. Wait 1 minute until the microcomputer is
prepared for operation.