![Daikin FAQ100CVEB Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/daikin/faq100cveb/faq100cveb_operation-manual_2460327009.webp)
English
5
If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING [°C]
HEATING [°C]
D
B: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote con-
troller is 16 C to 32 C.
Regarding places for installation
• Is the air conditioner installed at a well-venti-
lated place where there are no obstacles
around?
• Do not use the air conditioner in the following
places.
a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring
resort
d.Where there are considerable voltage fluctua-
tions such as a factory or plant
e.Vehicles and vessels
f
.Where there is much spray of oil and vapor
such as a cookery, etc.
3. OPERATION RANGE
OUTDOOR
UNIT
INDOOR
OUTDOOR
TEMPERA-
TURE
TEMPERA-
TURE
HUMIDITY
RZQG
DB
18 to 37
80% or
below
DB
–15 to 50
WB 12 to 28
RZQSG71·
100·140
DB
21 to 37
80% or
below
DB
–10 to 43
WB 14 to 28
RZQ200
DB
21 to 37
80% or
below
DB
–5 to 46
WB 14 to 28
OUTDOOR UNIT
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
RZQG
DB
10 to 27
DB
–19.5 to 21
WB
–20 to 15.5
RZQSG71
DB
10 to 30
DB
–14 to 21
WB
–15 to 15.5
RZQSG100·140 DB
10 to 28
DB
–14 to 21
WB
–15 to 15.5
RZQ200
DB
10 to 27
DB
–14 to 21
WB
–15 to 15
4. INSTALLATION SITE
g.Where there are machines generating electro-
magnetic waves
h.Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer about snow pro-
tection hoods, etc.
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by your-
self.
• Make sure that a separate power supply circuit
is provided for this air conditioner and that all
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.
Pay attention to running noises, too
• Are the following places selected?
a. A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b. A place where the hot wind discharged from the air
outlet of the outdoor unit and the running noises.
• Are you sure that there are no obstacles near
the air outlet of the outdoor unit?
Such obstacles may result in declined perfor-
mance and increased running noises.
• If abnormal noises occur in use, stop the oper-
ation of the air conditioner, consult your
dealer.
Regarding drainage of drain piping
• Is the drain piping carried out properly to
ensure complete drainage?
If drain piping is not carried out properly, dirt and
debris may be accumulated in the drain pipe and
cause water leakage. If it occurs, stop the air con-
ditioner and consult with you dealer for assis-
tance.
Read the operation manual that came with
the remote controller.
•
Operating procedure varies with heat pump type
and cooling only type. Contact your Daikin dealer
to confirm your system type.
•
To protect the unit, turn on the main power switch
6 hours before operation.
•
If the main power supply is turned off during oper-
ation, operation will restart automatically after the
power turns back on again.
5. OPERATION PROCEDURE
3P184442-10J_FM6.book Page 5 Wednesday, December 14, 2011 3:38 PM