IM 871-3 

Page 5 of 12

6.  Remove the grilles at the right and left ends of the primary 

discharge section (

Figure 10

). Position Primary Discharge 

Section on top of room cabinet. Through the openings 
provided by the removed grilles, position the mounting 
brackets at each end of the primary discharge section.

7.  Position the short (bottom) mounting bracket channel so 

the tabs on each end catch the underside of the grille tray 
of the cabinet/sleeve (see 

Figure 10

 detail). The long (top) 

bracket channel will sit on top of the turned flanges of the 

Primary Discharge Section. Adjust the bracket position 
and tighten the Phillips head screw on top of the mounting 
bracket to secure the discharge section to the cabinet.

NOTICE

  If an ExtendAire boost fan is installed, it's power cord will pass 

through the primary discharge section and over the mounting 
brackets, and not underneath.

Note:  Be sure the primary discharge section is positioned 

evenly end-to end with the cabinet/wall sleeve and that 
it is aligned squarely with the front edge of the cabinet/
wall sleeve

8.  Reinstall the touchpad controller by plugging in the 

communication cable into the receptacle in the control 
board. Snap the bezel into the control door opening (

Figure 

11

).

Figure 10: Position and tighten screws on mounting brackets to secure primary discharge section to cabinet/wall sleeve

Locate Right and Left Mounting Bracket

Primary Discharge Section

Mounting Bracket Assembly

Mounting Bracket Detail

Figure 11: Reinstall the touchpad communication cable 
and the touchpad bezel

Reinstall the touchpad 
control bezel into the 
control door opening 

Reinstall the touch-
pad communication 
cable to the control 
board

Go to page 6 and continue installation of ExtendAire compo-
nents.

Содержание ExtendAire IM 871-3

Страница 1: ...ty in Each Package Part Number Primary Discharge Section1 1 910106134 Shelf Discharge Assembly Primary Discharge Section1 1 Shelf Discharge Assembly 3 Foot Extension Section 1 Shelf Discharge Assembly...

Страница 2: ...llips head screw on top of the mounting bracket to secure the discharge section to the cabinet wall sleeve Note Be sure the primary discharge section is positioned evenly end to end with the cabinet w...

Страница 3: ...pad up and through the primary discharge section control door opening Check the communication cable for proper connection to the Touchpad and the control board Figure 5 Position and tighten screws on...

Страница 4: ...he underside of the touchpad control opening Unplug the touchpad com munication cable from the control board 3 Remove the two 2 screws located at each end of the cabinet wrap securing it to the wall s...

Страница 5: ...rd will pass through the primary discharge section and over the mounting brackets and not underneath Note Be sure the primary discharge section is positioned evenly end to end with the cabinet wall sl...

Страница 6: ...wall sleeve Refer to the specific configuration for installation details Note Upon completion of the selected configuration refer to steps 2 3 and 4 on page 7 Configuration 1 Shelf Discharge Assembly...

Страница 7: ...lles to the right and inactive grilles to the left when facing unit 3 Cover joints with trim pieces 4 Make sure there is at least 35 sq in free area return air opening from adjoining room Undercut doo...

Страница 8: ...d Figure 8 on page 4 To remove the chassis remove screws at locations shown in Note After completing steps 2a or 2b and 3a or 3b continue the Boost Fan installation as follows Figure 15 Remove the two...

Страница 9: ...igure 19 and insert the end of the orange wire detached from the plug connector into the kit provided butt connector and crimp In the opposite end of the butt connector insert the orange wire attached...

Страница 10: ...0 Remove the LUI touchpad from the unit control door opening 21 If primary ExtendAire discharge section has a reach through style door remove the discharge grille section by carefully straightening ta...

Страница 11: ...the unit to provide control to the boost fan Figure 23 29 Feed the LUI communication cable through the control door opening in the primary discharge section and plug into the COM terminal on the premi...

Страница 12: ...d pursuant to its standard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Representative for warranty details Refer to Form 933 430285Y To find your local Da...

Отзывы: