7 Installation
Installation manual
21
EZESHP20 EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726857-1 – 2023.03
c
b
b
Socket of the unit cable
c
2 pin connector of the connection cable
The door micro switch cable coming out of the unit is labelled "Door
micro switch".
The door micro switch is connected to the X63Y connector.
INFORMATION
Full installation instructions are delivered with the option
kit.
7.9
To install the cold chain data
logger
a
a
Cold chain data logger
1
Install the cold chain data logger (a).
2
Plug the 2 pin connector of the connection cable in the socket
of the unit cable.
The cold chain data logger is connected to the X104Y connector.
INFORMATION
Full installation instructions are delivered with the option
kit.
7.10
To install the fuel level probe
a b
a
Connector
b
Fuel level probe
1
Install the fuel level probe (b).
2
Guide the electrical cable from the tank to the unit.
The fuel level probe cable is connected to the X64Y connector.
INFORMATION
Full installation instructions are delivered with the option
kit.
7.11
To install the pre-filter heater
a
b
c
a
Fuel pre-filter
b
Connector
c
Pre-filter heater