D-EIMWC01008-16EU - 4/20 

 

 

Thank you for purchasing this Daikin air conditioner. 

 

 READ THIS MANUAL ATTENTIVELY BEFORE 

        STARTING UP THE UNIT. DO NOT THROW IT AWAY.  
        KEEP IT IN YOUR FILES FOR FUTURE REFERENCE. 
 
        IMPROPER INSTALLATION OR ATTACHEMENT OF       
        EQUIPMENT OR ACCESSORIES COULD RESULT IN  
        ELECTRIC SHOCK, SHORT CIRCUIT, LEAKS, FIRE OR 
        OTHER DAMAGE TO THE EQUIPMENT. BE SURE  
        ONLY TO USE ACCESSORIES MADE BY DAIKIN  
        WHICH ARE SPECIFICALLY DESIGNED FOR USE  
        WITH THE EQUIPMENT AND HAVE THEM  
        INSTALLED BY A PROFESSIONAL. 
 
        IF UNSURE OF INSTALLATION PROCEDURES OR  
        USE, ALWAYS CONTACT YOUR DAIKIN DEALER FOR 
        ADVICE AND INFORMATION. 
 
 
 
 
 
 
 
 
 
 
 

Содержание EWLD J Series

Страница 1: ...Condenserless water cooled screw chillers EWLD110J SS EWLD265J SS EWLH 80J SS EWLH190J SS EWLS 110J SS EWLS270J SS Refrigerant R 134a R1234ze R513A English 2 Deutsch 13 Fran ais 25 Nederlands 36 Espa...

Страница 2: ...to replace such personnel EWWD120J SS 280J SS EWWH090J SS 200J SS EWWS120J SS 270J SS EWLD 110J SS 265J SS EWLH 80J SS 190J SS EWLS 110J SS 270J SS Label Identification 1 Unit nameplate data 5 Manufa...

Страница 3: ...1234ZE 9 8 5 ADDITIONAL GUIDELINES FOR SAFE USE OF R1234ZE E FOR EQUIPMENT LOCATED IN THE OPEN AIR 9 8 6 ADDITIONAL GUIDELINES FOR SAFE USE OF R1234ZE E FOR EQUIPMENT LOCATED IN A MACHINERY ROOM 9 9 M...

Страница 4: ...PER INSTALLATION OR ATTACHEMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK SHORT CIRCUIT LEAKS FIRE OR OTHER DAMAGE TO THE EQUIPMENT BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHIC...

Страница 5: ...1600 1607 Operation weight Kg 1663 1675 Connections Chilled water inlet outlet 2 inch 3 Condenser water inlet outlet 2 inch 4 2 Victaulic coupling Model EWLD J 110 130 145 165 195 Dimensions HxWxL mm...

Страница 6: ...ion with Glycol Fixed minimum capacity at 100 2 Operation with Glycol below 4 C Evap LWT 3 Some units could work partialized in this area EWWH J EWLH J 1 Operation with Glycol Fixed minimum capacity a...

Страница 7: ...ing in the unit to a minimum It drilling is impreventable remove the iron filling thoroughly in order to prevent surface rust 6 UNPACKING AND PLACING THE UNIT 1 Remove the wooden beams from the unit 2...

Страница 8: ...1 66 19 33 10 2 01 9 4 01 29 7 27 48 12 53 67 19 78 9 2 09 10 4 15 30 7 48 49 12 85 68 20 23 8 2 17 11 4 29 31 7 70 50 13 18 69 20 69 7 2 26 12 4 43 32 7 92 51 13 51 70 21 16 6 2 34 13 4 58 33 8 15 52...

Страница 9: ...ity with the directives along with the documentation Before machine installation and commissioning the people involved in this activity must have acquired the information necessary to carry out these...

Страница 10: ...e done with due consideration of local airflow patterns accounting for location sources of ventilation and louvers Consideration shall also be given to the possibility of mechanical damage or contamin...

Страница 11: ...technicians Before beginning any work on the system the personnel shall assure that all security precautions have been taken Always protect the operating personnel with personal protective equipment a...

Страница 12: ...the product NOTE Take care for contamination of the remote condenser In order to avoid blocking of the system It is impossible for the manufacturer to control the contamination of the foreign condens...

Страница 13: ...ansmitting vibration and noise 6 For units in double circuit configuration with common leaving water control ELWT be sure to foresee an insertion hole for the additional water temperature sensor Senso...

Страница 14: ...relef valve on the condenser and pipe to each pressure relief valve on the evaporator Cross section and length of the discharge line must comply with local codes 15 FIELD WIRING All field wiring and...

Страница 15: ...sent to specific refuse collection centres Oil must be collected and sent to specific refuse collection centres 16 BEFORE STARTING The unit should not be started not even for a very short period of ti...

Страница 16: ...p VFD D L Demand Limit DI Digital Inputs DO Digital Outputs DPS Double Set Point EF Esternal Fault EFS Evaporator Flow Switch EFS 1 Evaporator Flow Switch 1 EFS 2 Evaporator Flow Switch 2 GA General A...

Страница 17: ...D EIMWC01006 11EU 17 20 17 FACTORY AND FIELD CHARGED UNITS INSTRUCTIONS Errore Non si possono creare oggetti dalla modifica di codici di campo 18 FIELD CHARGED UNITS INSTRUCTIONS...

Страница 18: ...rigerant charge Factory Field h Greenhouse gas emission of the total refrigerant charge expressed as tonnes of CO2 equivalent m Refrigerant type n GWP Global Warming Potential p Unit serial number 2 T...

Страница 19: ...of its content and the products and services presented therein Specification are subject to change without prior notice Refer to the data communicated at the time of the order Daikin Applied Europe S...

Страница 20: ...D EIMWC01006 11EU 20 20...

Отзывы: