2/7
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
User settings
└─
Preset values
└─
Room temperature
7.4.1.1
R/W
[3-07]~[3-06], step: A.3.2.4
21°C
7.4.1.2
R/W
[3-07]~[3-06], step: A.3.2.4
19°C
7.4.1.3
R/W
[3-08]~[3-09], step: A.3.2.4
24°C
7.4.1.4
R/W
[3-08]~[3-09], step: A.3.2.4
26°C
└─
LWT main
7.4.2.1
[8-09]
R/W
[9-01]~[9-00], step: 1°C
45°C
7.4.2.2
[8-0A]
R/W
[9-01]~[9-00], step: 1°C
40°C
7.4.2.3
[8-07]
R/W
[9-03]~[9-02], step: 1°C
18°C
7.4.2.4
[8-08]
R/W
[9-03]~[9-02], step: 1°C
20°C
7.4.2.5
R/W
-10~10°C, step: 1°C
0°C
7.4.2.6
R/W
-10~10°C, step: 1°C
-2°C
7.4.2.7
R/W
-10~10°C, step: 1°C
0°C
7.4.2.8
R/W
-10~10°C, step: 1°C
2°C
└─
Quiet level
7.4.4
R/W
0: Level 1
1: Level 2
2: Level 3
└─
Electricity price
7.4.5.1
[C-0C]
[D-0C]
R/W
0,00~990/kWh
0/kWh
7.4.5.2
[C-0D]
[D-0D]
R/W
0,00~990/kWh
0/kWh
7.4.5.3
[C-0E]
[D-0E]
R/W
0,00~990/kWh
0/kWh
└─
Fuel price
7.4.6
R/W
0,00~990/kWh
0,00~290/MBtu
8,0/kWh
└─
Set weather dependent
└─
Main
└──────────────────
Set weather-dependent heating
7.7.1.1
[1-00]
Set weather-dependent heating
Low ambient temp. for LWT main zone heating
WD curve.
R/W
-40~5°C, step: 1°C
-10°C
7.7.1.1
[1-01]
Set weather-dependent heating
High ambient temp. for LWT main zone heating
WD curve.
R/W
10~25°C, step: 1°C
15°C
7.7.1.1
[1-02]
Set weather-dependent heating
Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~[9-00]°C, step: 1°C
45°C
7.7.1.1
[1-03]
Set weather-dependent heating
Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
35°C
└──────────────────
Set weather-dependent cooling
7.7.1.2
[1-06]
Set weather-dependent cooling
Low ambient temp. for LWT main zone cooling
WD curve.
R/W
10~25°C, step: 1°C
20°C
7.7.1.2
[1-07]
Set weather-dependent cooling
High ambient temp. for LWT main zone cooling
WD curve.
R/W
25~43°C, step: 1°C
35°C
7.7.1.2
[1-08]
Set weather-dependent cooling
Leaving water value for low ambient temp. for
LWT main zone cooling WD curve.
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
7.7.1.2
[1-09]
Set weather-dependent cooling
Leaving water value for high ambient temp. for
LWT main zone cooling WD curve.
R/W
[9-03]~[9-02]°C, step: 1°C
18°C
Installer settings
└─
System layout
└─
Standard
A.2.1.1
[E-00]
R/O
0~5
1: Minichiller
A.2.1.2
[E-01]
R/O
0~1
0: 8
A.2.1.3
[E-02]
R/O
0: Type 1 (*1)
1: Type 2 (*2)
A.2.1.7
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
A.2.1.8
[7-02]
R/O
0: 1 LWT zone
A.2.1.9
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
A.2.1.A
[E-04]
R/O
0: No
1: Yes
A.2.1.B
R/W
0: At unit
1: In room
A.2.1.C
[E-0D]
Glycol present
R/W
0: No
1: Yes
└─
Options
A.2.2.B
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
└──────────────────
Control box
A.2.2.E.1
[E-03]
R/W
0: No BUH
1: 1 step
2: 2 steps
A.2.2.E.2
[5-0D]
R/W
0~5
1: 1P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,(1/1+2)
A.2.2.E.3
[D-01]
R/W
0: No
1: Active open
2: Active closed
A.2.2.E.5
[C-05]
R/W
1: Thermo ON/OFF
2: C/H request
└──────────────────
Option box
A.2.2.F.1
[C-02]
R/W
0: No
1: Bivalent
2: -
3: -
BUH type
Preferential kWh rate
Contact type main
Ext. backup heat src
Pump operation mode
Power saving possible
User interface location
External sensor
Backup heater steps
Unit type
Compressor type
Indoor software type
Unit control method
Number of LWT zones
High
Medium
Low
Eco (cooling)
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
Comfort (heating)
Eco (heating)
Comfort (cooling)
Field settings table
Installer setting at variance with
default value
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
4P469115-1B - 2017.06
(*1) EWYQ*_(*2) EWAQ*