Daikin EWAD TB Скачать руководство пользователя страница 5

 

 

D

–EIMAC01502–18_03EN - 5/25 

INTRODUCTION   

This  manual  provides  information  on  the  standard  functions  and  procedures  of  all  units  in  the  series  and  is  an 
important supporting document for qualified personnel, but can never replace it.  
All  units  are  delivered  with 

wiring  diagrams

certified  drawings,

 

nameplate

;  and 

DOC  (Declaration  Of 

Conformity)

; these documents show all technical data for the unit you have bought. In case of any discrepancies 

between the contents of the manual and the documentation provided with the unit, always rely on the unit because  

it 

is an integral part of this manual.

 

Read this manual carefully before installing and starting up the unit. 
Improper installation could result in electric shock, short-circuits, leaks, fire or other damage to the equipment or injure 
to people.  
The unit must be installed by professional operators / technicians in compliance with the laws in force in the country 
of installation.  
The start up of the unit must also be performed by authorized and trained personnel and all activities must be carried 
out in compliance, in full compliance with local laws and regulations.  

INSTALLATION AND START UP ARE ABOSOLUTELY FORBIDDEN IF ALL INSTRUCTIONS  CONTAINED IN 
THIS MANUAL ARE NOT CLEAR. 

 

If you are unsure about assistance and for more information, contact an authorized representati ve of the 
manufacturer.

 

1.1 Precautions against residual risks  

1.  install the unit according to the instructions set out in this manual 
2.  regularly carry out all the maintenance operations foreseen in this manual  
3.  wear protective equipment (gloves, eye protection, hard hat, etc.) suited to the work in hand; do not wear clothes 

or accessories that can get caught or sucked in by flows of air; tie back long hair before entering the unit  

4.  before opening the machine panelling make sure that it is firmly hinged to the machine 
5.  the fins on heat exchangers and the edges of metal components and panels can cause cuts  
6.  do not remove the guards from mobile components while the unit is operating  
7.  make sure that mobile component guards are fitted correctly before restarting the unit 
8.  fans, motors and belts drives might be running: before entering, always wait for these to stop and take appropriate 

measures to prevent them from starting up 

9.  the surfaces of the machine and pipes can get very hot or cold and cause the risk of scalding  
10.  never exceed the maximum pressure limit (PS) of the water circuit of the unit.  
11.  before removing parts on the pressurised water circuits, close the section of the piping concerned and drain the 

fluid gradually to stabilise the pressure at the atmospheric level 

12.  do not use your hands to check possible refrigerant leaks 
13.  disable the unit from the mains using the main switch before opening the control panel  
14.  check that the unit has been grounded correctly before starting it  
15.  install the machine in a suitable area; in particular, do not install it outdoors if it is intended for use indoors  
16.  do  not  use  cables  with  inadequate  sections  nor  extension  cord  connections,  even  for  very  short  periods  or 

emergencies 

17.  for  units  with  power  correction  capacitors,  wait  5  minutes  after  removing  the  electric  power  supply  before 

accessing the inside of the switch board 

18.  if the unit is equipped with centrifugal compressors with integrated inverter, disconnect it from the mains and wait 

a minimum of 20 minutes before accessing it to carry out maintenance: residual energy in the components, which 
takes at least this length of time to dissipate, poses the risk of electrocution 

19.  the  unit  contains  pressurised  refrigerant  gas:  the  pressurised  equipment  must  not  be  touched  except  during 

maintenance, which must be entrusted to qualified and authorised personnel  

20.  connect up the utilities to the unit following the indications set out in this manual and on the panelling of the unit 

itself 

21.  In  order  to  avoid  an  environmental  risk,  make  sure  that  any  leaking  fluid  is  collected  in  suitable  devices  in 

accordance with local regulations. 

22.  if a part needs to be dismantled, make sure it is correctly re-assembled before starting the unit 
23.  when the rules in force  require the installation of fire -fighting systems near the machine,  check that these are 

suitable  for  extinguishing  fires  on  electrical  equipment  and  on  the  lubricating  oil  of  the  compressor  and  the 
refrigerant, as specified on the safety data sheets of these fluids 

24.  when the unit is equipped with devices for venting overpressure (safety valves): when these valves are triggered, 

the refrigerant gas is released at a high temperature and speed; prevent the release of gas from harming people 
or objects and, if necessary, discharge the gas according to the provisions of EN 378-3 and the local regulations 
in force. 

Содержание EWAD TB

Страница 1: ...Operation and Maintenance Manual Air cooled chiller with screw compressor EWAD T B EWAD T C Refrigerant R 134a Rev 03 Date 01 2023 Supersedes D EIMAC01502 18_02EN Installation Operation and Maintenanc...

Страница 2: ...cifications 19 7 Operation 19 7 1 Operator s responsibilities 19 8 Maintenance 20 8 1 Routine maintenance 20 8 2 Unit Maintenance and Cleaning 21 8 3 Microchannel Coil Maintenance 22 9 Service and lim...

Страница 3: ...D EIMAC01502 18_03EN 3 25 Figure 1 Typical refrigerant circuit Dual Circuit Water inlet and outlet are indicative Please refer to the machine dimensional diagrams for exact water connections...

Страница 4: ...icator 8 Economizer heat exchanger 9 Solenoid valve 10 Termostatic expansion valve 12 Electronic expansion valve 13 Evaporator S T 14 Pressure relief valve Pset 15 5 bar 15 Access fitting SAE Flare va...

Страница 5: ...aces of the machine and pipes can get very hot or cold and cause the risk of scalding 10 never exceed the maximum pressure limit PS of the water circuit of the unit 11 before removing parts on the pre...

Страница 6: ...te transport can cause damage to the machine and even leaking of the refrigerant fluid Before start up the machine must be checked for leaks and repaired accordingly 37 the accidental discharge of ref...

Страница 7: ...k to people animals and or objects 3 RECEIVING THE UNIT The unit must be inspected for any possible damage immediately upon reaching final place of installation All components described in the deliver...

Страница 8: ...lection of specific options such as high ambient kit brine version etc which allow the unit to operate with evaporator leaving water temperature below 4 C and or ambient temperature at full load above...

Страница 9: ...applied to the electrical panel Double circuits unit Label Identification 1 Manufacturer s logo 5 Cable tightening warning 2 Gas type 6 Non flammable gas symbol 3 Hazardous Voltage warning 7 Unit nam...

Страница 10: ...ncy rescue personnel of the building or the Health Emergency Service wait without leaving the injured person alone until the rescue operators come give all necessary information to the rescue operator...

Страница 11: ...necessary to install additional sound attenuation devices 5 3 Moving and lifting Avoid bumping and or jolting during loading unloading unit from the truck and moving it Do not push or pull the unit fr...

Страница 12: ...D EIMAC01502 18_03EN 12 25 Unit with 6 lifting points The drawing shows only the 12 fans version The lifting mode is the same for the different number of fans Unit with 8 lifting points...

Страница 13: ...plate spacers Before unit commissioning the flatness must be verified by using a laser levelling device or other similar devices The flatness shall not be over 5 mm for units within 7 m length and 10...

Страница 14: ...me height as the unit this must be installed at a distance no lower than 3000 mm In case of two chillers installed in free field minimum recommended distance between them is 3600 mm in case of two chi...

Страница 15: ...rcuit on the right is working quite normally In order to avoid the hot air recirculation due to dominant winds the installation where all chillers are aligned to the dominant wind is preferred see fig...

Страница 16: ...point drain device at the system s lowest point 5 Neither the evaporator nor the heat recovery device must be positioned at the system s highest point 6 A suitable device that can maintain the water s...

Страница 17: ...SiO2 l 50 NO Chlorine molecular mg Cl2 l 5 0 5 5 9 Evaporator and recovery exchangers anti freeze protection All evaporators are supplied with a thermostatically controlled anti freeze electrical res...

Страница 18: ...er to guarantee the respect of this value e g using recirculating bypass valve Figure 7 Water piping connection for evaporator opt 78 79 80 81 ID DESCRIPTION a SINGLE PUMP b TWIN PUMP c DRAIN d AUTOMA...

Страница 19: ...nection works the unit must be switched off and secured This product complies with EMC standards for industrial environments Therefore it is not intended for use in residential areas e g installations...

Страница 20: ...d environments Table 2 Standard Routine Maintenance Plan List of Activities Weekly Monthly Note 1 Yearly Seas Onal Note 2 General Reading of operating data Note 3 X Visual inspection of unit for any d...

Страница 21: ...he electrical panel X Verify operation of all ventilation fans in the electrical panel X Refrigeration circuit Check for any refrigerant leakage X Verify refrigerant flow using the liquid sight glass...

Страница 22: ...remove soluble salts and revitalize the unit NOTE Harsh chemicals household bleach or acid cleaners should not be used to clean E coated coils These cleaners can be very difficult to rinse out of the...

Страница 23: ...he product as following instructions the refrigerant charge for each circuit 1 2 3 added during commissioning on site charging the total refrigerant charge 1 2 3 calculate the greenhouse gas emission...

Страница 24: ...ementing the Directive 2012 19 EU RAEE Lead batteries must be collected and sent to specific waste collection centers Avoid the escape of refrigerant gases into the environment by using suitable press...

Страница 25: ...e of its content and the products and services presented therein Specification are subject to change without prior notice Refer to the data communicated at the time of the order Daikin Applied Europe...

Отзывы: