4 Operation

Operation manual

12

ETVH/9W + ETBH/9W

Daikin Altherma 3 H MT F+W

4P634883-1 – 2021.03

Possible read-out information

In menu…

You can read out…

[8.1] 

Energy data

Produced energy, consumed
electricity, and consumed gas

[8.2] 

Malfunction history

Malfunction history

[8.3] 

Dealer information

Contact/helpdesk number

[8.4] 

Sensors

Room, tank or domestic hot
water, outside, and leaving water
temperature (if applicable)

[8.5] 

Actuators

Status/mode of each actuator

Example: 

Domestic hot water

pump ON/OFF

[8.6] 

Operation modes

Current operation mode

Example: 

Defrost/oil return

mode

[8.7] 

About

Version information about the
system

[8.8] 

Connection status

Information about the connection
status of the unit, the room
thermostat and the LAN adapter.

[8.9] 

Running hours

Running hours of specific system
components

4.6

Space heating/cooling control

4.6.1

Setting the space operation mode

About space operation modes

Your unit can be a heating or a heating/cooling model:

▪ If your unit is a heating model, it can heat up a space.

▪ If your unit is a heating/cooling model, it can both heat up and cool

down a space. You have to tell the system which operation mode
to use.

To tell the system which space operation to use, you can:

You can…

Location

Check which space operation mode is
currently used.

Home screen

Set the space operation mode permanently. Main menu

Restrict automatic changeover according to
a monthly schedule.

To set the space operation mode

1

Go to [4.1]: 

Space heating/cooling

 > 

Operation

mode

2

Select one of the following options:

Heating

: Only heating mode

Cooling

: Only cooling mode

Automatic

The 

operation 

mode 

changes

automatically  between  heating  and  cooling  based
on the outdoor temperature. Restricted per month
according  to  the 

Operation  mode  schedule

[4.2].

To restrict automatic changeover according to a schedule

Conditions: 

You set the space operation mode to 

Automatic

.

1

Go to [4.2]: 

Space heating/cooling

 > 

Operation

mode schedule

.

2

Select a month.

3

For each month, select an option:

Reversible

: Not restricted

Heating only

: Restricted

Cooling only

: Restricted

4

Confirm the changes.

4.6.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.

1

Go to [1]: 

Room

.

Room

1

2

Adjust the desired room temperature.

+

21

°C

1

a

b

Room

a

 Actual room temperature

b

 Desired room temperature

If scheduling is on after changing the desired room temperature

▪ The  temperature  will  stay  the  same  as  long  as  there  is  no

scheduled action.

▪ The  desired  room  temperature  will  return  to  its  scheduled  value

whenever a scheduled action occurs.

You  can  avoid  scheduled  behaviour  by  (temporarily)  turning  off
scheduling.

To turn off room temperature scheduling

1

Go to [1.1]: 

Room

 > 

Schedule

.

2

Select 

No

.

4.6.3

To change the desired leaving water
temperature

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.
Only adjust the leaving water temperature settings in case
of problems.

You  can  use  the  leaving  water  temperature  setpoint  screen  to  read
out and adjust the desired leaving water temperature.

Содержание ETVH12S18EA6V

Страница 1: ...rma 3 H MT F W English Operation manual Daikin Altherma 3 H MT F W ETVH12S U 18EA6V ETVH12S U 23EA6V ETVH12S18EA9W ETVH12S23EA9W ETVX12S18EA6V ETVX12S23EA6V ETVX12S18EA9W ETVX12S23EA9W ETBH12EF6V ETBH...

Страница 2: ...15 4 9 2 2 points curve 16 4 9 3 Slope offset curve 16 4 9 4 Using weather dependent curves 17 5 Energy saving tips 17 6 Maintenance and service 18 6 1 Overview Maintenance and service 18 7 Troublesh...

Страница 3: ...you turn OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature control and extern...

Страница 4: ...s changed the new preferred temperature at X1 is unequally higher than the preferred temperature at X2 X1 X2 c d Y1 Y2 Y3 Y4 a b Offset When offset is changed the new preferred temperature at X1 is eq...

Страница 5: ...Off To change the tank temperature setpoint In Reheat only mode you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank 5 2 Adjus...

Страница 6: ...tion Addendum book for optional equipment Additional info about how to install optional equipment Format Paper in the box of the indoor unit Digital files on http www daikineurope com support and manu...

Страница 7: ...nit is not in operation Continuous blue Operation The unit is in operation Blinking red Malfunction A malfunction occurred See 7 1 To display the help text in case of a malfunction 418 for more inform...

Страница 8: ...Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Activa...

Страница 9: ...Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy i...

Страница 10: ...ature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving...

Страница 11: ...ting cooling operation ON b Space heating cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 4 4 2 To turn ON or OFF Spac...

Страница 12: ...ne of the following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restrict...

Страница 13: ...o produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tank tempe...

Страница 14: ...emperature control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week schedule or the content of a selected day schedule 3 Pro...

Страница 15: ...ach character of the schedule name 4 To name the current schedule browse through the character list and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the n...

Страница 16: ...rature Go to the next temperature Confirm changes and proceed 4 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently incre...

Страница 17: ...2 6 Main zone Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to i...

Страница 18: ...on fluorinated greenhouse gases requires that the refrigerant charge of the unit is indicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2 equivalent tonnes GWP value of...

Страница 19: ...er the domestic hot water production and space heating For ETBH X The backup heater automatically takes over the heat load and the booster heater in the optional tank takes over the domestic hot water...

Страница 20: ...ventilated Reason Refrigerant might leak into the water circuit and subsequently into the room when you purge air from the heat emitters or collectors 8 Disposal NOTICE Do NOT try to dismantle the sy...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...4P634883 1 2021 03 Copyright 2021 Daikin 4P634883 1 0000000U Verantwortung f r Energie und Umwelt...

Отзывы: