Installation manual
3
ERHQ011~W1 + ERLQ011~W1
Outdoor unit for air to water heat pump
4PW54249-1
Model
ERLQ units include special equipment (insulation, bottom plate
heater,...) to ensure good operation in areas where low ambient
temperature can occur together with high humidity conditions. In
such conditions the ERHQ models may experience problems with
severe ice build up on the aircooled coil. In case such conditions are
expected, the ERLQ must be installed instead. These models contain
countermeasures (insulation, bottom plate heater,...) to prevent
freeze up.
Accessories
■
Check if the following accessories are included with the unit
See the figure below for the location of the accessories.
■
Possible options
Handling
As shown in the figure below, slowly move the unit by grabbing the
left and right grips. Position your hands on the corner instead of
grabbing the air inlet to avoid deforming the casing.
S
ELECTING
INSTALLATION
SITE
1
Select an installation site where the following conditions are
satisfied and that meets with your customer's approval.
-
Places which are well-ventilated.
-
Places where the unit does not bother next-door neighbours.
-
Safe places which can withstand the unit's weight and
vibration and where the unit can be installed level.
-
Places where there is no possibility of flammable gas or
product leak.
-
The equipment is not intended for use in a potentially
explosive atmosphere.
-
Places where servicing space can be well ensured.
-
Places where the indoor and outdoor units' piping and wiring
lengths come within the allowable ranges.
-
Places where water leaking from the unit cannot cause
damage to the location (e.g. in case of a blocked drain pipe).
-
Places where the rain can be avoided as much as possible.
-
Do not install the unit in places often used as work place.
In case of construction works (e.g. grinding works) where a
lot of dust is created, the unit must be covered.
-
Do not place any objects or equipment on top of the unit (top
plate).
-
Do not climb, sit or stand on top of the unit,
-
Be sure that sufficient precautions are taken, in accordance
with relevant local and national regulations, in case of
refrigerant leakage.
2
When installing the unit in a place exposed to strong wind, pay
special attention to the following.
Strong winds of 5 m/sec or more blowing against the outdoor
unit's air outlet causes short circuit (suction of discharge air),
and this may have the following consequences:
-
Deterioration of the operational capacity.
-
Frequent frost acceleration in heating operation.
-
Disruption of operation due to rise of high pressure.
-
When a strong wind blows continuously on the face of the
unit, the fan can start rotating very fast until it breaks.
Refer to the figures for installation of this unit in a place where
the wind direction can be foreseen.
NOTE
■
An ERLQ0*BA outdoor unit can only be
connected to an EKHBH/X016BA indoor unit
(bottom plate heater at outdoor unit has to be
controlled by indoor unit).
■
An ERHQ0*BA outdoor unit can be connected to
an EKHBH/X016BA indoor unit or to an EKHBH/
X016AA/AB indoor unit (if a bottom plate heater
kit is required, see "Possible options" on page 3).
Installation manual
1
Cable tie
2
Fluorinated greenhouse gases
label
1
Multilingual fluorinated
greenhouse gases label
1
Bottom plate heater
Drain socket
ERLQ
Standard
Use prohibited
ERHQ
Optional kit
(a)
(a) Combination of both options is prohibited.
Optional kit
1
1
Accessories
EKBPHT16Y*
EKBPHTH16A
EKHBH/X016AA/AB
Possible
Not allowed
EKHBH/X016BA
Possible
Possible
To avoid injury, do not touch the air inlet or aluminium fins
of the unit.
CAUTION
■
Make sure to provide for adequate measures in order
to prevent that the outdoor unit be used as a shelter
by small animals.
■
Small animals making contact with electrical parts can
cause malfunctions, smoke or fire. Please instruct the
customer to keep the area around the unit clean.