15 Technical data
Installer reference guide
80
ERLQ004~0 EHVH/X04+0 EHVH/X08S26CA
Daikin Altherma - Low Temperature Split
4P313775-1C – 2012.11
15.3
Components
15.3.1
Components: Outdoor unit
b
c
d
e
f
j
h
i
g
a
l
k
a
Switch box main PCB (inverter and control PCB)
b
Terminal communication and power supply
c
Service PCB
d
4-way valve
e
Electronic expansion valve (main)
f
Accumulator
g
Compressor
h
Liquid stop valve
i
Gas stop valve
j
Service port
k
Fan motor
l
Heat exchanger
15.3.2
Components: Switch box (outdoor unit)
a
c
d
e
b
a
Service PCB
b
Terminal communication cable
c
Terminal power supply cable
d
Earth connection
e
Wire clamp
15.3.3
Components: Indoor unit
h
f
e
a
c
d
k
b
b
g
y
v
s
l
m
j
r
u
w
x
i
dd
n
p (180 l)
n
q
o
n
t
n
p (260 l)
o
z
z
y
i
x
aa
bb
cc
a
Space heating cooling out
b
Shut-off valves (accessory)
Allows isolation of the indoor unit water circuit side from the
residential water circuit side.
c
Domestic hot water out
d
Refrigerant liquid connection R410A
e
Refrigerant gas connection R410A
f
Domestic hot water in
g
Fill valve (accessory)
h
Space heating cooling in
i
Expansion vessel (10 l)
j
Pressure relief valve
Prevents excessive water pressure in the water circuit by
opening at 3 bar.
k
Water filter
Removes dirt from the water to prevent damage to the pump or
blockage of the heat exchanger.
l
Heat exchanger
m
Water pump
Circulates the water in the water circuit.
n
Thermistors
Determines the water and refrigerant temperature at various
points in the circuit.
o
Drain caps
p
Tank thermistors (180 l/260 l)
q
Domestic hot water tank drain valve
Empties the full tank.
r
Switch box
Contains the main electronic and electrical parts of the indoor
unit.
s
Backup heater thermal protector
The protector activates when the temperature of the backup
heater becomes too high.
t
Drain collector (EHVX models only)
u
Drain gutter (EHVX models only)