t
yPiCal
W
iring
d
iagraMs
MicroTech III controller with I/O expansion module – with waterside
economizer (WSE) 208/230, 460, 575-60-3
COMPRESSO
R
PROTECTOR
MODUL
E
T2
T1
S2
S1
M2
M1
COMPRESSO
R
PROTECTOR
MODUL
E
T2
T1
S2
S1
M2
M1
LED1
SLTS
RV
LED1
GRY 46
BLU 41
BLU 40
RA
T
LED2
IOEX
P
CO
S
BLK 60
BLK 61
SEE NOTE
LED2
JP_
2
JP_
3
JP_
4
JP_
5
JP_
6
JP_
7
JP_
8
H1
H2
N3
N2
N1
L1-3
L1-2
L1-1
H3
H5
H4
H7
H6
H8
H9
TB
2
TEST-1
TB
1
TB
3
RUN PRG
JTAG
BLU 20
LP
2
HP
2
SLTS
2
1
1
1
1
1
JP
1
JP8
JTAG
RV
2
YEL 11
RED 12
CC
1
BRN 52
BRN 53
BLU 42
BLU 43
BLK 62
BLK 63
YEL 19
LP
BLK 10
YEL 8 (L2)
RED 9 (L3)
BLK 7 (L1)
R1
HP
BRN 55
BRN 54
GRN/YEL 97
FAN
MOTOR
LW
T
DA
T
BLK
BL
U
YEL 45
BLK/RED-460V
RED-208V
ORG-230V
BLK-575V
1
JP_
1
BLK 4
YEL 5
RED 6
YEL 27
BLU 28
CC2
YEL 34
BLK 33
L3
L2
L1
X2
BL
K
YE
L
BLU
YEL 89
BLK 81
TB
2
RE
D
OL
T1
T2
L1
T3
L2
L3
CO
M
24
V
X1
T1
TB
1
L1
T2
L3
L2
L1
SERVICE
&
DISCONNE
W
L3
L2
BLK 1
YEL 2
RED 3
T3
GN
D
YEL 18
YEL 31
RED 32
L1
L2
L3
CM-1
BLK 30
CM-2
BLK/RED - 460V
RED - 208
v
ORG - 230V
BLK - 575
V
YEL
77
BL
U
75
BL
U
72
BL
U
70
YEL
76
BL
U
74
BL
U
73
BL
U
71
RED 35
YEL
BLU 15
YEL 14
45
2
R3
45
2
R4
87
86
TO GRY 46
10
11
85
WS
E
M
EW
T
CO
E
TO CO
S
R4
BL
U
104
YE
L
103
R3
YEL
101
BL
U
10
2
IO Expansion Module
C - 24VAC COMMON
O - W3 - HEAT -3
G - FAN
Y1 - COOL - 1
Y2 - COOL 2
W1 - HEAT - 1
W2 - HEAT - 2
A - ALARM OUTPUT
5 - DC SIGNAL COM
4 - ROOM SENSOR/TO
3 - SETPOINT ADJUST
2 - FAN MODE/HT-CL-AUTO
1 - ROOM SENSOR LED
U - MARK IV - OCC/UNOCC
E - EMER SHTDN INPUT
R - 24VAC
Communication
Module
MicroTech III Controller
24V NO
24VAC COMMON
24V NC
Note: Switch L2/L3 fan
motor wires for
left-hand unit
Note:
Wiring diagrams are typical. For the
latest drawing version refer to the
wiring diagram located on the inside of
the controls access panel of the unit.
Gray tinted areas in the wiring dia-
gram: Units with factory installed com-
munication module include Discharge
Air Temperature (DAT) and Return Air
Temperature (RAT) sensors shipped
loose and are field installed. The Leav
-
ing Water Temperature (LWT) sensor
is factory installed.
Legend
Item Description
CC1
Circuit 1 Compressor Contactor
CC2
Circuit 2 Compressor Contactor
CM1
Circuit 1 Compressor
CM2
Circuit 2 Compressor
COS
Condensate Overflow Sensor
HP
Circuit 1 High Pressure Switch
HP2
Circuit 2 High Pressure Switch
IOEXP
I/O Expansion Board / Harness
LED1
LED Annunciator / Harness
LED2
LED Annunciator / Harness
*RAT
Return Air Temperature
*LWT
Leaving Water Temp Sensor
LP
Circuit 1 Low Pressure Switch
LP2
Circuit 2 Low Pressure Switch
SLTS
Circuit 1 Suction Line Temp Sensor
SLTS2
Circuit 2 Suction Line Temp Sensor
MTIII
MicroTech III Main Board
R1
Fan Motor Starter
RV
Circuit 1 Reversing Valve Solenoid
RV2
Circuit 2 Reversing Valve Solenoid
TB1
Power Terminal Block
X1
75 VA Transformer
X2
50 VA Transformer
*DAT
Discharge Air Temp Sensor
*EWT
Entering Water Temp Sensor
WSE
Waterside Economizer
TB2
Power Terminal Block
Notes:
1. “Run/Prg” Jumper to be in “Run” position for
normal operation
* Leaving Water (LWT), Discharge Air (DAT)
and Return Air Temperature (RAT) sensors are
field installed.
_ _ _ _ Denotes optional feature
IM 1059-12 LARGE VERTICAL WSHP
37 www.DaikinApplied.com