Outdoor Unit • Daikin Altherma flex type• EMRQ-A
1
11
•
Heating • Daikin Altherma flex type
24
11
Installation
11 - 1 Installation Method
4TW59911-2A
EMRQ8-16A
Heat/cooling meters
Space heat/cooling side
Heat and cooling meter
Between DHW-I/U
Heat meter(*)
DHW Tapping side
Heat meter(*)
Nominal I/U capacity
5,6 kW
Nominal I/U capacity
9 kW
Temperature
T
max
(°C)
85
85
85
85
T
min
(°C)
3
3
3
3
_
T
max
(K)
40
40
40
83
_
T
min
(K)
3
3
3
3
Flow
Nominal flow Qn (at
_
T=5K)
0,96
1,55
Nominal flow Qn (at
_
T=10K)
0,48
0,77
Nominal flow Qn (at
_
T=15K)
0,32
0,52
Maximum flow Q
max
2,1
2,1
1,7
2,1
Minimum response flow
(l/h)
10
10
10
10
Flow direction
1 direction
1 direction
1 direction
1 direction
pressure
Nominal pressure
(bar)
0,5-3,0
0,5-3,0
0,5-3,0
Pressure loss at Q
n
(bar)
<0,25
<0,25
<0,25
Maximum pressure loss at Q
max
(bar)
0,35
0,35
0,35
Maximum working pressure
(bar)
3
3
3
10
Data storage
Minimum storage interval
1 month
1 month
1 month
1 month
Minimum storage capacity
13 months
13 months
13 months
13 months
Register
(kWh)
heat + cooling values (**)
heat + cooling values (**)
heat values
heat values
(*)
Check local regulations and heat meter documentation for the possiblity of mountaing the tank heat meter in the drinking water circuit
(**) In case of heating only units, heat meter is sufficient (no heat + cooling meter)
Other - Refer to specifications of tank and indoor unit for selection of required connections with field supplied piping and heat meters
- Minimum requirement for data read out is a display
- No corrosion if contact with water
- The local regulations for the use of heat meteres and heat + cooling meters (mounting, sealing, operation . . . ) must be complied with.
In absence of regulations, it is advised to consult the heat meter supplier and/or service company
Electrical power meter (kWh meter)
Before selecting the electrical power meter, it is advised to check the read-out possibilities with the heat meter supplier and/or service company
Selection to be based on outdoor unit specifications
Minimum requirement for data read out is a display