Daikin EKHBRD011ADV1 Скачать руководство пользователя страница 2

 

Operation manual

 

1

 

EKHBRD011~Y1

 

Indoor unit for air to water heat pump system and options

 

4P402192-1A – 2015.04

 

C

 

ONTENTS

 

Page

 

Introduction ..................................................................................... 1

 

General information .................................................................... 1

Scope of this manual .................................................................. 1

 

Quick start-up of the unit ............................................................... 2

 

Space heating operation .................................................................... 2
Domestic water heating operation ...................................................... 2

 

Operation of the unit....................................................................... 2

 

Remote controller buttons and icons .......................................... 3

Setting the clock.......................................................................... 4

Space heating operation (h) ....................................................... 5

 

Room temperature control.................................................................. 5
Leaving water temperature control ..................................................... 5

 

Domestic water heating operation (w) ........................................ 7

 

Automatic storage............................................................................... 7
Manual storage................................................................................... 8
Reheat................................................................................................ 9
Disinfection operation ......................................................................... 9

 

Emergency operation.................................................................. 9

Other operation modes ............................................................... 9

 

Start up operation (d) ......................................................................... 9
Defrost operation (d) .......................................................................... 9
Quiet mode operation (s).................................................................... 9

 

Simultaneous demand of space heating and 
domestic water heating ............................................................. 10

Temperature read-out mode ..................................................... 10

Schedule timer operation .......................................................... 10

 

Space heating .................................................................................. 10
Domestic water heating .................................................................... 12
Quiet mode ....................................................................................... 12

 

Programming and consulting the schedule timer...................... 12

 

Programming space heating............................................................. 13
Programming quiet mode or domestic water heating ....................... 14
Consulting programmed actions....................................................... 14
Tips and tricks .................................................................................. 15

 

Operating the remote alarm option ........................................... 15

Operating the optional remote controller .................................. 15

Field settings............................................................................. 16

 

Procedure ......................................................................................... 16
Field settings table............................................................................ 17

 

Maintenance .................................................................................. 19

 

Maintenance activities ...................................................................... 19
Important information regarding the refrigerant used ....................... 19

 

Troubleshooting ............................................................................ 19

Disposal requirements ................................................................. 19

 

The English text is the original instruction. Other languages are
translations of the original instructions.

This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.

 

I

 

NTRODUCTION

 

General information

 

Thank you for purchasing this unit.

The unit is the indoor part of the air to water ERSQ or ERRQ heat
pump. The unit is designed for floor standing indoor installation and
used for heating applications. The unit can be combined with space
heating radiators (field supply) and with an EKHTS* domestic hot
water tank (option).

A remote controller with room thermostat functionality is standard
supplied with this unit to control your installation.

Refer to the installation manual for the list of options.

 

Scope of this manual

 

This manual describes how to start up and switch off the unit, set
parameters and configure the schedule timer by means of the
controller, maintain the unit and solve operational problems.

 

EKHBRDY1
EKHBRDY1
EKHBRDY1

 

Indoor unit for air to water heat pump system

and options

 

Operation manual

 

CAREFULLY READ THIS OPERATION MANUAL
BEFORE USING THE UNIT. IT WILL TELL YOU HOW TO
USE THE UNIT PROPERLY AND HELP YOU IF ANY
TROUBLE OCCURS. AFTER READING THE MANUAL,
FILE IT AWAY FOR FUTURE REFERENCE.

 

 

This unit contains electrical and hot parts.

 

 

Before operating the unit, make sure the installation
has been carried out correctly by a professional
dealer.

If you feel unsure about operation, contact your dealer
for advice and information.

 

NOTE

 

An EKHBRD indoor unit can only be connected to an
ERSQ or ERRQ outdoor unit.

 

Refer to the installation manual of the indoor unit for
installation procedures.

Содержание EKHBRD011ADV1

Страница 1: ...OPERATION MANUAL EKHBRD011ADV1 EKHBRD014ADV1 EKHBRD016ADV1 EKHBRD011ADY1 EKHBRD014ADY1 EKHBRD016ADY1 Indoor unit for air to water heat pump system and options...

Страница 2: ...y or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children sh...

Страница 3: ...sh the button See Automatic storage on page 7 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual sto...

Страница 4: ...installation purposes only 13 NOT AVAILABLE This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficient permissio...

Страница 5: ...on as well as the shift value in case not zero will display 31 ROOM TEMPERATURE ADJUST BUTTONS and These multi purpose buttons are used to adjust the current room temperature set point in normal opera...

Страница 6: ...ater temperature control In this mode heating will be activated as required by the water temperature set point The set point can be set manually through the schedule timer or weather dependent automat...

Страница 7: ...ings 3 00 Low ambient temperature Lo_A low outdoor temperature 3 01 High ambient temperature Hi_A high outdoor temperature 3 02 Set point at low ambient temperature Lo_Ti the target outgoing water tem...

Страница 8: ...atus defines whether the weather dependent domestic water heating is turned ON 1 or OFF 0 If enabled the storage set point will be set weather dependent In case of a higher ambient temperature e g dur...

Страница 9: ...point for the domestic hot water storage temperature is reached It can also be stopped at any time by pushing the button NOTE If weather dependent domestic water heating is enabled b 02 the storage t...

Страница 10: ...lf is done by the heater kit If there are no error conditions in leaving or returning water thermistors the heater kit can start to follow emergency operation Other operation modes Start up operation...

Страница 11: ...lation is controlled by the schedule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pr...

Страница 12: ...ommand 13 00 and will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last progr...

Страница 13: ...water heating and quiet mode program depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a daily basis Take your time to enter all data accu...

Страница 14: ...emperature 10 Use the and buttons to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water...

Страница 15: ...tions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted By pressing the button several times you return to previous steps in this procedur...

Страница 16: ...actions except those with a higher action number than the one that is displayed E g when the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted D...

Страница 17: ...ceed as follows 1 Press the button for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed t...

Страница 18: ...A 15 10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1...

Страница 19: ...storage temperature 70 45 75 1 C 04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation r...

Страница 20: ...the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...4P402192 1A 2015 04 Copyright 2015 Daikin...