EKHBH/X016AA
Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system
4PW36977-1B
Operation manual
4
26
SANITARY WATER HEATING BUTTON
v
This button enables or disables heating of the sanitary water.
This button is not used when the sanitary water tank is not
installed.
27
WEATHER DEPENDENT SET POINT BUTTON
ba
This button enables or disables the weather dependent set point
function which is available in space heating operation only.
If the controller is set in permission level 2 or 3 (refer to
), the weather dependent set point button
will not be operable.
28
INSPECTION/TEST OPERATION BUTTON
z
This button is used for installation purposes and changing field
settings. Refer to
29
PROGRAMMING BUTTON
<
This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.
30
SCHEDULE TIMER BUTTON
r
/
p
The main function of this multi-purpose button is to enable/
disable the schedule timer.
The button is also used to program the controller. The function of
the button depends on the actual status of the controller or on
previous actions carried out by the operator.
If the controller is set in permission level 3 (refer to
), the schedule timer button will not be
operable.
31
TIME ADJUST BUTTON
pi
and
pj
These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water outlet temperature of the
indoor unit, outdoor ambient temperature and sanitary water
temperature) and in schedule timer programming mode.
32
TEMPERATURE ADJUST BUTTONS
bi
and
bj
These multi-purpose buttons are used to adjust the current set
point in normal operation mode or in schedule timer
programming mode. In weather dependent set point mode the
buttons are used to adjust the shift value. Finally, the buttons are
also used to select the weekday while setting the clock.
33
SANITARY TEMPERATURE ADJUST BUTTONS
wbi
and
wbj
These buttons are used to adjust the current set point of the
sanitary water temperature.
The buttons are not used when the sanitary water tank is not
installed.
34
QUIET MODE BUTTON
s
This button enables or disables quiet mode.
If the controller is set in permission level 2 or 3 (refer to
), the quiet mode button will not be
operable.
Setting up the controller
After initial installation, the user can set the clock and day of the
week.
The controller is equipped with a schedule timer that enables the
user to schedule operations. Setting the clock and day of the week is
required to be able to use the schedule timer.
Setting the Clock
1
Hold down the
pr
button for 5 seconds.
The clock read-out and the day of week indicator start flashing.
2
Use the
pi
and
pj
buttons to adjust the clock.
Each time the
pi
or
pj
button is pressed, the time will
increase/decrease by 1 minute. Keeping the
pi
or
pj
button pressed will increase/decrease the time by 10 minutes.
3
Use the
bi
or
bj
button to adjust the day of the week.
Each time the
bi
or
bj
button is pressed the next or
previous day is displayed.
4
Press the
<
button to confirm the current set time and day of the
week.
To leave this procedure without saving, press the
pr
button.
If no button is pressed for 5 minutes the clock and day of the
week will return to their previous setting.
Setting the schedule timer
To set the schedule timer, refer to chapter
consulting the schedule timer" on page 7
NOTE
Remark that pushing the
y
button has no influence
on the sanitary water heating. Sanitary water heating
is only switched on or off by means of the
v
button.
NOTE
The clock needs to be set manually. Adjust the setting
when switching from summertime to wintertime and
vice versa.