9
|
Electrical installation
Installer reference guide
93
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1B – 2021.10
Item
Description
Remote indoor sensor
See:
▪
Installation manual of the remote indoor
sensor
▪
Addendum book for optional equipment
Wires: 2×0.75 mm²
[A.2.2.F.5]=2 (
External sensor
=
Room
sensor
)
[A.3.2.3]
Ext. room sensor offset
LAN adapter
See:
▪
Installation manual of the LAN adapter
▪
Addendum book for optional equipment
Wires: 2×(0.75~1.25 mm²). Must be
sheathed.
Maximum length: 200 m
See
for room thermostat (wired or wireless):
In case of…
See…
Wireless room thermostat
▪
Installation manual of the wireless room
thermostat
▪
Addendum book for optional equipment
Wired room thermostat
without multi-zoning base unit
▪
Installation manual of the wired room
thermostat
▪
Addendum book for optional equipment
Wired room thermostat with
multi-zoning base unit
▪
Installation manual of the wired room
thermostat (digital or analogue) + multi-zoning
base unit
▪
Addendum book for optional equipment
▪
In this case:
-
You need to connect the wired room
thermostat (digital or analogue) to the
multi-zoning base unit
-
You need to connect the multi-zoning base
unit to the outdoor unit
-
For cooling/heating operation, you also
need to implement a relay (field supply, see
addendum book for optional equipment)
LAN adapter – System requirements
The requirements posed on the Daikin Altherma system depend on the LAN
adapter application/system layout (app control):
Содержание EHFZ03S18DJ3V
Страница 1: ...Installer reference guide Daikin Altherma 3 R F ERLA03DAV3 EHFZ03S18DJ3V...
Страница 211: ......
Страница 212: ...4P596821 1B 2021 10 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...