ESIE13-03
|
Part 3. Repair
2. Unit specific repair procedures
13/05/15
|
Version 2.0
Page 95
Ground source heat pump
4. Carefully pull the A4P PCB (4) at the right side and unlatch the 4 pcb supports (5) one by one using a small pliers.
5. Remove the A4 PCB (4).
6. Unplug the jumper wire from connector CN1 (6) on the A4P PCB.
Figure 14 - Replacing the A4P PCB
Installation
1. Proceed in reverse order.
2. Install the jumper wire on connector CN1 on the A4P PCB.
2.2.2.4 Procedure: replacing the A8P PCB
Removal
1. Unplug connector X80A (1) from the A8P PCB (4).
2. If required, note the position of the wires connected to terminals X800 (3) and X801M (2) on PCB A8P (4).
3. Remove the field connected wiring on terminals X800 (3) and X801M (2) on PCB A8P (4).
4. Carefully pull the PCB A8P (4) at the right side and unlatch the 4 PCB supports (5) one by one using a small pliers.
5. Remove the PCB A8P (4).
1. X1-4
4. A4P PCB
2. YC, Y1-4
5. PCB support
3. CN2
6. CN1
3 1
5
2
4
6
Содержание EGSQH10S18AA9W
Страница 1: ...Service Manual Ground source heat pump EGSQH10S18AA9W ESIE13 03 Version 2 0 ...
Страница 82: ...ESIE13 03 Part 2 Troubleshooting 4 Component checklist Page 82 13 05 15 Version 2 0 Ground source heat pump ...
Страница 148: ...ESIE13 03 Part 3 Repair 2 Unit specific repair procedures Page 148 13 05 15 Version 2 0 Ground source heat pump ...