ESIE13-03
|
Part 3. Repair
2. Unit specific repair procedures
Page 136
13/05/15
|
Version 2.0
Ground source heat pump
2.2.21.2 Procedure
Removal
1. Unplug connector X21A (1) from the A9P PCB (2).
2. Attach a pull line (5) of approximately 2 meter to the electronic expansion valve wire (4).
3. Cut the tie wraps (6).
4. While guiding the pull line (5) through the grommet (3), pull the electronic expansion valve wire (4) until the pull line (5) surfaces
at the heat pump module.
5. Detach the pull line (5) from the electronic expansion valve wire (4).
Figure 55 - Replacing the electronic expansion valve K1E electromagnet
6. Cut the tie wrap (2).
7. Remove the expansion valve electromagnet (1) from the electronic expansion valve.
8. Remove the expansion valve electromagnet (1).
I
NFORMATION
The electronic expansion valve electromagnet is replaced together with the electronic expansion valve electromagnet
wire. To facilitate the installation of the new electronic expansion valve electromagnet, a pull line must be attached to
the electronic expansion valve electromagnet wire before removal.
1. X21A
4. Electronic expansion valve wire
2. A9P PCB
5. Pull line (not illustrated)
3. Grommet
6. Tie wrap (not illustrated)