5 Maintenance and service
Operation manual
8
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P3517501 – 2013.06
5
Maintenance and service
5.1
Overview: Maintenance and
service
The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.
As end user, you have to:
▪ Keep the user interface clean with a soft damp cloth. Do NOT use
any detergents.
▪ Regularly check if the water pressure indicated on the manometer
is above 1 bar.
Refrigerant
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol. Do NOT vent gases into the atmosphere.
Refrigerant type: R410A
Global warming potential value: 1975
Periodical inspections for refrigerant leaks may be required
depending on the applicable legislation. Please contact your installer
for more information.
5.2
To find the contact/helpdesk
number
Go to [6.3.2]:
> Information > Error handling > Contact/helpdesk
number.
6
Troubleshooting
6.1
Symptom: You are feeling too cold
(hot) in your living room
Possible cause
Corrective action
The desired room temperature is
too low (high).
Increase (decrease) the desired
room temperature.
If the problem recurs daily, do
one of the following:
▪ Increase (decrease) the room
temperature preset value.
▪ Adjust the room temperature
schedule.
The desired room temperature
cannot be reached.
Increase the desired leaving
water temperature in accordance
with the heat emitter type.
6.2
Symptom: The water at the tap is
too cold
Possible cause
Corrective action
You ran out of domestic hot
water because of unusual high
consumption.
If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy.
If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally.
If the problems recurs daily, do
one of the following:
▪ Increase
the
DHW
tank
temperature preset value.
▪ Adjust
the
DHW
tank
temperature
schedule.
Example:
Program
to
additionally
heat
up
the
DHW tank to a preset value
(Storage eco = lower tank
temperature) during the day.
The desired DHW tank
temperature is too low.
7
Glossary
DHW = Domestic hot water
Hot water used, in any type of building, for domestic
purposes.
LWT = Leaving water temperature
Water temperature at the water outlet of the heat pump.