
Operation Manual
EDBE81-327
20
Photocatalytic Air Purifiers
4. Remove the filter roll.
5. Remove the opposing pole plates (two).
• Push and expand the knobs on the outside and raise up the knob
side of the opposing pole plates and then remove them on the
outside.
CAUTION
• When cleaning be careful not to cut your hands on the opposing
pole plates. (Wearing rubber gloves is safer.)
ATTENTION
• The ionizing line is located at
the rear of the opposing pole
plates.
When removing the plates, be
careful not to catch and cut
the ionizing line.
6. Clean the opposing pole plates.
• After using a vacuum cleaner to remove any dust, clean with
water.
• If very dirty, clean using a neutral household cleaner or after
applying the cleaner, rub with a rag or soft brush and sufficiently
clean with water until no cleaning agent is left and then dry in the
shade.
ATTENTION
• Do not use water to clean the plasma ionizer (resin part).
• After cleaning, wipe with a cloth until none is remaining.
• Do not use acidic or alkaline cleaners. Rust may occur.
7. Clean the plasma ionizer.
• Use water to slightly moisten the ionizing line and surrounding
resin parts and then use a tissue to gently wipe along the ionizing
line.
CAUTION
• When cleaning be careful not to cut your hands on the ionizing line.
(Wearing rubber gloves is safer.)
• Be careful not to snag or cut the ionizing line. If the ionizing line is
cut, request the Daikin dealer to replace it.
If the unit is operated with the ionizing line cut, there will be no dust
collection. The “Clean sign” may also flash.
• After cleaning, thoroughly dry the plasma ionizer. If the unit is oper-
ated before it is dry, the “Clean indicator” may also flash.
8. Set the opposing pole plates in the plasma ionizer
(resin part).
(1) Securely insert the opposing pole plates into the hooks (two at
center) of the plasma ionizer.
(2) While pressing and expanding the knobs (one on each side) of
the plasma ionizer towards the outside, securely insert the
opposing pole plates.
ATTENTION
• When removing the opposing pole plates, be careful not to catch
and cut the ionizing line.
9. Install the filter roll in its original position.
• Refer to procedure 7 on Page 9.
10. Install the plasma ionizer in its original configuration.
• Refer to procedure 8 on Page 9.
11. Install the front panel to its original position.
• Refer to procedure 5 on Page 8.
Knob
Knob
Opposing pole plates (2)
Opposing pole plate
Ionizing line
Filter roll
Acidic
cleaners
Alkaline
cleaners
Neutral
cleaners
Ionizing line
(1) Hook
(2) Knob
(2) Knob
Opposing pole
plate
Plasma ionizer
(Resin part)
10