9
|
Electrical installation
Installer reference guide
120
EBLA04~E23V3 + EDLA04~E23V3
Daikin Altherma 3 M
4P685228-1A – 2022.05
180°
X5M
3 4
1314
3
Connect the high voltage wiring as follows:
X10M.1
X10M.2
X10M.3
X10M.4
L
L
N
N
1
2
1
High voltage Smart Grid contact 1
2
High voltage Smart Grid contact 2
180°
1 2 3 4
X10M
4
Fix the cables with cable ties to the cable tie mountings. If necessary, bundle
excessive cable length with a cable tie.
9.2.15 To connect the WLAN cartridge (delivered as accessory)
[D]
Wireless gateway
1
Insert the WLAN cartridge into the cartridge slot on the user interface of the
indoor unit.