WIRING DIAGRAMS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
DSC036* /DSC048* SINGLE PHASE
208-230V/1PH/60HZ DIRECT DRIVE
H
RCCF
T
PU
BR
C
T1
S
T1
BK
O
1
4
BR
1
BR
T1
BK
9
RD
COMP
R
BR
RCCF
T2
3
C
W2
T
Y1
PLF 1
3
T
YL/PK
PU
F
7
5
PU
T3
G
T2
COMPONENT LEGEND
BL
L1
SUPPLY VOLTAGE
CM
BK
R
EM
/
L1
C
RD
YL
6
0
BC
BIR
C
CM
COMP
EM
GND
HPS
LPS
PLF
RCCF
TB1
TR
WH
C
A
GR
CM
W1
YL
8
E
RD
M
C
C
2
YL
S
L2
BLOWER CAPACITOR
BLOWER INTERLOCK RELAY
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUPIMENT GROUND
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
CONDENSER FAN
TERMINAL BLOCK (24V SIGNAL)
TRANSFORMER
TR
OF OVER CURRENT PROTECTION
BL
BK
PU
COMP
SEE UNIT RATING PLATE FOR TYPE AND SIZE
208-240V
O
208-240/1/60
R
2
0
8
-
2
4
0
Y2
/
GND
6
1
PB
TB1
BL
208-240/1/60 0140L02896-B
SEE NOTE 3
24V
RD
RD
T2
L2
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST
105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE
M1 OR M2 WIRE TO COM TERMINAL ON EBTDR
AND PLACE WIRE REVMOVED FROM COM ON
EMPTY M1 OR M2 TERMINAL.
3. FOR 208 VOLT TRANSFORMER OPERATION
MOVE BLACK WIRES FROM TERMINAL
3 TO TERMINAL 2 ON TRANSFORMER.
4. USE COPPER CONDUCTORS ONLY
++
USE N.E.C. CLASS 2 WIRE
5. ECONOMIZER PLUG LOCATED IN THE RETURN
AIR COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.
6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS.
WH
GR
F
LPS
YL/PK
BL
RD
OR
Y1
YL
W
BL
G
R
OR
W
NO ECONOMIZER
G
OR
RD
Y1
PK
WH
W
R
RD
WH
GR
C
O
R
YL
O
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTAT
FIELD WIRING
BL
C
O
2 STAGE COOLING
TB1
G
R
W
C
O
TB1
TB1
Y
W
O
R
G
C
W
Y2
G
R
C
O
Y1
STAT
STAT
STAT
C
BL/PK
HPS
BL
PU
BR
C
RD
2
3
K1
RD
BK
BK
BC
BK
24V
COM
TR
UP
BL
M2
BK
240
GR
NC
SPEED
EBTDR
PU
R
XFMR-R
XFMR-C
BL
G
K1
M1
EM
NO
1
SEE
NOTE #2
RD
PU
BL
C
3 SPEED
BR
BL
BK
208
PK
RD
BK
RD
BR
BL
BIR
BK
BR
EBTDR
BR
8
9
7
R
O
HPS
C
LPS
SEE NOTE 5
TB1
5
6
PLF 1
G
C
Y1
W1
4
THER+
W2
PLF 2
R
R
C
G
EBTDR
XFMR
PU
ALTERNATE
MOTOR
6-WIRES
SEE TABLE 1
BC
3 SPEED
BL
EM
RD
BK
BR
RD
PU
TABLE 1
ALTERNATE MOTOR WIRING
TABLE 2
SPEED TAPS
COLOR TERMINATION
RD
LOW
H
BL
OR
BK
BK
PU
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
GR GREEN
WIRE CODE
BL BLUE
PU PURPLE
PK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
YL
1
3
2
OR
RD
H
RD
BK
BL
PU
COM (EBTDR)
M1 (EBTDR)
M2 (EBTDR)
PIN 1 (24V XFMR)
BL
MED
BK
HIGH
3
2
6
7
9
1 4
8
5
YL
3
2
6
7
9
1 4
8
5
S1
S2
R
R
Y2
Y2
Y2
Y2
YL
Y
SMOKE/FIRE
DETECTOR
REPLACES
JUMPER
S1
S2
BL
BK
PK
PK
BR
EQUIPMENT
GROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED
CONTROL
PLUG
CONNECTION
CONTROL
BOX
++
++
OPTIONAL
LOW VOLTAGE
Содержание DSC Series
Страница 69: ...69 THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 70: ...70 THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 71: ...71 THIS PAGE LEFT INTENTIONALLY BLANK...