35
TROUBLESHOOTING CHARTS
LED
ACTIVITY
DESCRIPTION
COLOR
MINIMUM
LOCKOUT PERIOD
POSSIBLE CAUSES
CORRECTIVE ACTIONS
STEADY ON OEM FACTORY TEST
MODE
AMBER
N/A
RAPID
FLASH
FIELD TEST MODE AMBER
N/A
1 FLASH
LOW FLAME SENSE AMBER
N/A
• Flame sensor incorrectly
positioned in burner
flame.
• Flame sensor is coated
and/or oxidized.
• Improper gas pressure ot
combustion air.
• Inspect for proper sensor alignment.
• Clean flame rod.
• Compare gas pressure to rating plate info.
Adjust as needed.
2 FLASHES
ID PLUG FAILURE
AMBER HARD LOCKOUT
HEATING MODE
• Improper ID plug.
• Replace ID plug.
3 FLASHES CONTROL FUSE OPEN AMBER
5 MINUTES
• Blown fuse.
• Inspect wiring for damage, mis-wiring or short to
ground.
• Replace integrated control module fuse (3A).
STEADY ON
STANDBY NORMAL
OPERATION NO
THERMOSTAT CALL
GREEN
N/A
RAPID
FLASH
CLEAR ERROR
HISTORY
GREEN
N/A
1 FLASH
CALL FOR
HEATING
GREEN
N/A
2 FLASHES
CALL FOR
COOLING
GREEN
N/A
3 FLASHES
CONTINUOUS
FAN OPERATION
GREEN
N/A
Содержание DP14UM