39
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOL
T
A
G
E
!
DIS
C
ONNECT
AL
L
POW
E
R BEF
O
RE
SERVICI
NG OR IN
S
T
A
L
L
IN
G
T
H
IS
UNIT
.
M
U
L
T
IPL
E
PO
W
E
R SO
UR
CES M
A
Y BE P
R
ESEN
T
.
F
A
IL
URE
T
O
DO SO
M
A
Y CAUS
E PROP
ERT
Y
DAM
AG
E,
PERSONAL
I
N
J
U
R
Y
OR DE
A
T
H
.
WIRING DIAGRAMS
RD
BK
P
O
W
E
R DIAGRAM
DCC0
72
2 SPEED EM
2 STAGE C
O
M
P
5. SEE ACCE
SSORY
KIT
LIT
E
R
A
TUR
E FOR OP
T
IONA
L CONV
ENI
ENCE
OU
T
LET
WIRING DI
AGR
AM
.
4
SE
E CONTROL
DIAGR
AM
FOR CO
NTRO
L TRAN
SFORM
ER
LOW
VOL
T
A
G
E
CONNECT
IONS
3 208/230V
SU
PPLY
POW
ER UNI
T
S
AR
E
FAC
T
ORY CON
NEC
T
ED
T
O
TH
E CONTROL
TR
AN
SFORM
ER
240V
T
AP.
MO
VE WIR
E
CONNECT
ION FROM
24
0V
T
A
P
T
O
208V T
AP WHEN
208V POW
ER
SU
PPLY
IS US
ED.
2 THE CONTROL
TRAN
SFORM
ER H
AS MU
LT
IP
LE
HIGH
VO
LT
AGE T
APS.
EN
SURE
WIR
E
CONNECT
IONS
AR
E CORRECT
FOR UNIT
SU
PPL
Y
VOLT
A
G
E
RA
T
ING
1.
RE
PLAC
EM
EN
T
WIR
E
MU
ST
BE
SAM
E SIZE
AND
T
Y
PE OF IN
SU
LA
T
ION
AS ORIGIN
A
L (USE
COP
PER CONDU
CTOR
S ONLY).
UNI
T
T
E
R
M
INA
LS AR
E NO
T
DE
SIGNED FOR O
THER CONDU
CTOR
S
THE
US
E OF O
THER
T
Y
PE COND
UCTORS
M
AY C
A
U
SE DA
M
A
G
E
T
O
THE UNI
T
NOTES
:
01
40L049
75-A
GND
L1
L2
L3
LINE
V
O
LT
AG
E
BK
RD
RD
RD
PU
BK
RD
OR
BK
RD
BK
YL
FC
B
K
(12)
BK(13)
BK(11)
BK
OR
RD
BK
RD
BK
OR
RD
OR
BK
RD
OR
L1
L2
L3
T1
T2
T3
BC1
BK
BK
RD
L1
L2
L3
T1
T2
T3
BC2
RD
OR
L1
L2
L3
T1
T2
T3
CC
OR
RD
BK
OR
RD
YL
BK
T1
T3
COM
P
T2
EM
OR
RD
BK
WH
OR
BL
GY
BL
YL
GY
BL
YL
GR
RD
BK
2,3
4
24V
CNTL
V
O
LT
AG
E
L
INE
VO
LT
AGE
TR1
LO
W
VOLT
A
G
E
FI
E
LD
W
IR
IN
G
HIGH
VO
LT
AGE
Y2
2ND S
T
A
G
E
COO
L CA
LL
(OUT
PUT)
Y1
1ST
ST
A
G
E
COO
L CA
LL
(OUT
PUT)
W2
2ND S
TAG
E
HEA
T CA
LL
(OUT
PUT)
W1
1S
T
ST
AG
E
HEA
T
CA
LL
(OUT
PUT)
G
C
R
TB1
CONNECT
ION
24V
AC-P
W
R
(INPUT)
THERM
OSTAT
IN /
OUT
24V
AC - C
O
M
(INPUT)
FAN C
A
LL
(OUT
PUT)
THE
R
MOSTA
T C
O
NN
E
CTI
O
N
S
YELLOW/ PINK STRIPE
YELLOW
YL/PK
BL/PK
BK
W
IR
E
C
O
D
E
BLACK
BL
BLUE
BR
BROWN
GR
GREEN
GY
GRAY
OR
ORANGE
PK
PINK
PU
PURPLE
RD
RED
WH
WHITE
YL
BLUE/ PINK STRIPE
FACT
O
R
Y
W
IR
IN
G
LOW VOL
T
AGE
HIGH VOLT
AGE
HIGH VOLTAGE
OP
TI
ONAL
BK
RD
BK
RD
OR
EM
ECON
EV
APORA
T
OR M
O
T
O
R
ECON
OM
IZ
ER
FC
FAN C
A
PACI
T
O
R
COM
PRE
S
SOR 2ND
S
T
AG
E
S
O
LEN
OID
CS
EV
AP
ORA
T
OR BLO
W
ER
T
IM
E
DE
LAY
RE
LAY
EB
TDR
T
ERM
INA
L BLOCK
3, L
O
W
VO
LT
AGE
PLU
G
/
CONNECT
OR,
M
A
LE
BLO
W
ER CON
T
A
CT
OR
BC
PLM
BLOW
ER RE
LAY
COM
PRE
SS
OR C
ONT
ACT
OR
CONDENSER M
O
TOR
COM
PRE
S
SOR
HIGH
PRE
S
SURE
S
W
ITCH
LOW
PRE
S
SURE
S
W
ITCH
PLU
G
/ CONNECT
OR,
F
E
M
A
LE
T
E
RM
INA
L BLOCK
1,
LOW
VOLT
A
GE
TRANSF
ORM
ER 1,
CON
TRO
LS
(LINE
VOLT
A
GE /
24
VAC)
CC
CM
COM
P
HPS
LPS
PLF
TB
1
TR1
C
OMP
O
N
E
NT
LE
G
E
ND
BR
TB3
E
Q
U
P
IM
E
N
T
G
R
O
U
N
D
G
N
D
CM
PU
BR
BK
GR
BK
BR
BK
BR
PU
PU
6
6
2 SPEED
EVAPOR
AT
OR MO
T
OR:
BLAC
K
LEAD
S FOR HIGH S
PEED O
P
ER
AT
ION,
AND
WHI
T
E
/ BLU
E / ORANG
E LEAD
S FOR LOW
SPEED O
PER
AT
ION.
7 CONDENS
ER W
IRING
SHOWN FOR (20
8/
23
0)V
MODE
LS. WIR
E
T
O
WIR
E
CONNECT
IONS
NO
T
PR
ESEN
T
ON (4
60
/5
75)V
MODE
LS
.
TH
E CONDENS
ER
MO
T
OR L
EAD
S CONNECT
DIREC
T
LY
T
O
FAN C
APACI
T
OR / COM
PR
ESSOR CONT
AC
T
OR.
7
POWER DIAGRAM FOR DCC072***V
(AIR CONDITIONER, 2 SPD EVAP FAN, 2 STAGE COMP, ALL VOLTAGES)
Содержание DCC048 SERIES
Страница 27: ...27 APPENDIX D WIRING DIAGRAMS ...
Страница 61: ...61 THIS PAGE LEFT BLANK INTENTIONALLY ...