![Daikin DC92SS Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/daikin/dc92ss/dc92ss_installation-instructions-manual_501997020.webp)
20
#
3
#1
#2
#4
#5
#6
#7
#8
#9
#10
#11
100 Degree
Elbow
Coupling
Figure 21
NOTE:
Drain components shown for information purposes only.
Figure 20
NOTE: Drain components shown for information purposes
only.
Field Supplied Drain
Drain the furnace and air conditioning coil if applicable,
in compliance with code requirements. In horizontal or
counterflow installations, a field installed rubber coupling will
allow the drain trap to be removed for cleaning. The drain
trap must be primed before initial furnace start up. When an
air conditioning coil drain is connected to the field supplied
furnace drain, it must be vented by an open tee installed at a
height no higher than the bottom of the furnace collector box
to prevent air conditioning condensate from backing up into
the furnace if the common drain was blocked.
Upflow Model Installed Vertically
The trap and factory installed hoses remain as shipped.
The furnace drain may exit either the right or left side of the
furnace cabinet. Both sides of the cabinet have two .875”
diameter holes which can be used interchangeably for drain
and low voltage wiring purposes. If a higher drain exit is
needed, a .875” diameter hole may be added in the area
shown in Figure 21. Any unused cabinet opening must be
sealed. Do not allow drain hose to sag or trap water.
Figure 21
Drain Exiting Right Side
1. Locate and Install the 45º pipe / hose drain coupling
from the outside of the cabinet (barbed end goes
in the cabinet) through hole in the right side of the
cabinet and secure with two field supplied #8 self-
tapping screws (see Figure 22).
2. Locate the long drain hose #3 and cut at line “A” .
3. Install large end of hose #3 to trap outlet and secure
with 1.25” clamp.
4. Install smaller end of hose #3 on 45º elbow and
secure with 1” clamp.
5. Refer to Field Supplied Drain section for instructions
on field supplied / installed drain on outlet of furnace
trap.
Drain Exiting Left Side
1.
Install the 45 degree pipe / hose drain coupling from
the outside of the cabinet (barbed end goes in the
cabinet) through the hole in the left side of the cabinet
and secure with two field supplied #8 self-tapping
screws (see Figure 22).
2. Locate the long drain hose #3 and cut at “B” line for a
17.5” cabinet; cut at line “C” for a 21” cabinet; do not
cut for a “D” width cabinet.
3. Install large end of hose #3 to trap outlet and secure
with 1.25” clamp.
4. Install smaller end of hose #3 on 45º elbow and
secure with 1” clamp.
5. Refer to Field Supplied Drain section for instructions
on field supplied / installed drain on outlet of furnace
trap.